2017
DOI: 10.1109/tia.2017.2726506
|View full text |Cite
|
Sign up to set email alerts
|

A Modular Active Front-End Rectifier With Electronic Phase Shifting for Harmonic Mitigation in Motor Drive Applications

Abstract: Abstract-In this paper, an electronic phase-shifting strategy has been optimized for a multi-parallel configuration of linecommutated rectifiers with a common dc-bus voltage used in motor drive application. This feature makes the performance of the system independent of the load profile and maximizes its harmonic reduction ability. In order to further reduce the generated low order harmonics, a dc-link current modulation scheme and its phase shift values of multi-drive systems have been optimized. Analysis, si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…where š‘‡ š‘  is the sampling time Then, the predicted rectifier currents (defined in continuous time by (5) in section II) are given by (9) in the discrete-time domain at sample (k+1).…”
Section: Finite Control Set Model Predictive Current Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…where š‘‡ š‘  is the sampling time Then, the predicted rectifier currents (defined in continuous time by (5) in section II) are given by (9) in the discrete-time domain at sample (k+1).…”
Section: Finite Control Set Model Predictive Current Controlmentioning
confidence: 99%
“…Multi-pulse transformer-based rectifiers like 12, 18 and 24 pulses rectifiers, can reduce the THD [8]. It is reported that THD is in the range of 15% using a 12-pulse rectifier [9]. However, its bulky structure makes it a less favorable choice.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, modular power converters with AFE rectifiers have been extensively utilized by motor drives to improve their harmonic characteristics and raise the overall power quality. In [13], a modular AFE rectifier with a common DC link is extended for multidrive configuration to mitigate harmonic distortions based on the electronic phase shifting technique. To elevate the modular AFE rectifier behavior, it is useful to separate the rectifier module from the drive unit and consider it as the main interface circuit between the AC power grid and the motor drive system's DC link and deploy a robust and feasible control strategy.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, a current modulation technique for the DR-EI is proposed in [31], [32], [33], [34], and [35] to mitigate specific harmonics. This current modulation technique is also utilised in a combination of DR-EI and parallel Silicon Controlled Rectifiers (SCR) with EI to improve the current harmonics [36], [37], [38].…”
Section: Introductionmentioning
confidence: 99%