2015
DOI: 10.1016/j.brachy.2015.01.003
|View full text |Cite
|
Sign up to set email alerts
|

A modified dose calculation formalism for electronic brachytherapy sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 10 publications
0
16
0
1
Order By: Relevance
“…TG-43 pomija wpływ tkanki, niejednorodność Natalia Matuszak / Zeszyty Naukowe WCO, Letters in Oncology Science 2017;14 (4):116-124 aplikatora oraz określone wymiary pacjentów. Obliczenia dawki przy użyciu formalizmu TG-43 dokonuje się wokół pojedynczego, centralnie umieszczonego źródła w kulistym fantomie wodnym [7][8][9][10][11][12][13][14][15]. Według założeń TG-186, dawki są wrażliwe na przekrój wspólnego oddziaływania woksel po wokselu, czyli w każdym elemencie objętości tkanki [16].…”
Section: • Pomiar Dawki Poprzez Tpsunclassified
“…TG-43 pomija wpływ tkanki, niejednorodność Natalia Matuszak / Zeszyty Naukowe WCO, Letters in Oncology Science 2017;14 (4):116-124 aplikatora oraz określone wymiary pacjentów. Obliczenia dawki przy użyciu formalizmu TG-43 dokonuje się wokół pojedynczego, centralnie umieszczonego źródła w kulistym fantomie wodnym [7][8][9][10][11][12][13][14][15]. Według założeń TG-186, dawki są wrażliwe na przekrój wspólnego oddziaływania woksel po wokselu, czyli w każdym elemencie objętości tkanki [16].…”
Section: • Pomiar Dawki Poprzez Tpsunclassified
“…6 Also, a new dose calculation formalism has been proposed for all eBT sources given their incompatibility with current TPSs. 7 The proposed formalism utilized the NISTK air (d = 50 cm) calibration standard instead of air-kerma strength. Given the advancements in source calibrations, dosimetry parameters, and dosimetry formalism, the objective of the current study was to independently evaluate the NIST eBT calibration standard using the Lamperti chamber and the reevaluated model S700 source design for a theoretical assessment oḟ K air (d = 50 cm) values.…”
Section: C Study Rationalementioning
confidence: 99%
“…Since this is a different quantity from AKS, this necessitates a modification in the formalism. [3] The major change is air kerma rate at 50 cm in air and the dose rate conversion, c. Thus the equation includes a value for the air kerma rate at 50 cm in air and the dose rate conversion for a given applicator, i. If the bare source is used the i=0 or if a titanium applicator is used then i=Ti.…”
Section: Calibration Of the Hdr Electronic Brachytherapy Sourcementioning
confidence: 99%
“…The 2.4 % uncertainty covers all of the various manufacturer sources and results in confidence in the calibration and measurement in the clinic using a well chamber. Electronic brachytherapy source calibrations will require a modification in the standard protocol as proposed by DeWerd et al [3]. Clinical physicists can be assured that HDR 192 Ir calibrations traceable to primary standards dosimetry laboratories around the world are very similar and accurate.…”
Section: Introductionmentioning
confidence: 99%