2020
DOI: 10.4103/ojo.ojo_196_2019
|View full text |Cite
|
Sign up to set email alerts
|

A modified air-assisted silicone oil removal from the anterior chamber

Abstract: Silicone oil (SO) is a commonly used tamponading agent in retinal detachment surgeries. Inadvertent anterior migration of SO and complete anterior chamber (AC) oil fill in an aphakic or pseudophakic eye is occasionally encountered. This can cause secondary glaucoma with very high intraocular pressure and pain. In this scenario, an urgent silicone oil removal (SOR) is warranted. Since SO is buoyant, in the supine position, it tends to rise anteriorly. Hence, removal of SO trapped in the AC will invariably lead … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…In their technique, Wahab et al removed the SO from the AC by gradually filling the AC with air by the use of a vitreo-retinal surgery air pump, while at the same time allowing the SO to either fall posteriorly to the posterior segment or to exit the eye through a paracentesis kept open by pressing on its posterior lip [38]. A risk arising from partial SO removal in the supine position is increased migration of SO from the vitreous cavity into the AC, following its tendency to float [39]. On the one hand, this makes SO removal from the AC inefficient and, on the other hand, increases the risk of retinal redetachment, as SO leaves the vitreous cavity.…”
Section: Silicone Oil Removalmentioning
confidence: 99%
See 1 more Smart Citation
“…In their technique, Wahab et al removed the SO from the AC by gradually filling the AC with air by the use of a vitreo-retinal surgery air pump, while at the same time allowing the SO to either fall posteriorly to the posterior segment or to exit the eye through a paracentesis kept open by pressing on its posterior lip [38]. A risk arising from partial SO removal in the supine position is increased migration of SO from the vitreous cavity into the AC, following its tendency to float [39]. On the one hand, this makes SO removal from the AC inefficient and, on the other hand, increases the risk of retinal redetachment, as SO leaves the vitreous cavity.…”
Section: Silicone Oil Removalmentioning
confidence: 99%
“…At the conclusion of surgery, sideports were closed with 10-0 nylon sutures in order to prevent loss of air and facedown positioning was prescribed for one week postoperatively. Possible complications include endothelial damage and Descemet membrane detachment [39].…”
Section: Silicone Oil Removalmentioning
confidence: 99%