1987
DOI: 10.1038/jcbfm.1987.18
|View full text |Cite
|
Sign up to set email alerts
|

A Modification of the Method for the Measurement of Cerebral Blood Flow Using [14C]Iodoantipyrine in Small Animals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

1987
1987
2011
2011

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 4 publications
0
9
0
Order By: Relevance
“…The method has been modified to overcome the need for continuous arte rial sampling in small animals by the simultaneous admin istration of [99mTc]pertechnate (Richards et al, 1987). Both [14C]iodoantipyrine at 5 MBq/kg body weight (Am ersham International) and [99mTc]pertechnate (10 MBq) in 0.4 ml saline were infused over 1 min at an increasing rate.…”
Section: Lcbf Measurementmentioning
confidence: 99%
“…The method has been modified to overcome the need for continuous arte rial sampling in small animals by the simultaneous admin istration of [99mTc]pertechnate (Richards et al, 1987). Both [14C]iodoantipyrine at 5 MBq/kg body weight (Am ersham International) and [99mTc]pertechnate (10 MBq) in 0.4 ml saline were infused over 1 min at an increasing rate.…”
Section: Lcbf Measurementmentioning
confidence: 99%
“…, 1986) or cats (Reivich et aI., 1968(Reivich et aI., , 1969 and newborn dogs (Batton et aI., 1983;Cavazutti and Duffy, 1982;Kennedy et aI., 1972) or monkeys (Hosokawa et aI., 1977). Recently, Richards et al (1987) proposed a modification of the e4C]iodoantipyrine technique for small animals by using a simultaneous infusion of e4C]iodoantipyrine and of [99mTc]pertechnetate. The 99mTc is counted externally by a detector placed over the chest.…”
mentioning
confidence: 99%
“…The choice of freely diffusible tracer for a given experiment will depend on the following parameters: spatial resolution, invasiveness, the ability to make serial measurc6ments and cost; these are shown in Table 1. In experiments where spatial resolution is more important than the need for serial measurements [14C]iodoantipyrine in conjunction with quantitative autoradiography is appropriate (Reivich et al 1969;Sakurada et al 1978;Richards et al 1987), whereas when the need for serial measurements is paramount, hydrogen clearance methods are suitable. Much of the equipment used for CBF measurement has been designed and built in Southampton.…”
Section: Molten Plastic Inmentioning
confidence: 99%