2007
DOI: 10.1016/j.arthro.2006.08.011
|View full text |Cite
|
Sign up to set email alerts
|

A Minimalist Approach to Hip Arthroscopy: The Slotted Cannula

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…The results of this human study underscored the difficulties and ergonomic challenges of human stifle arthroscopy and concluded that instruments or systems to decrease these issues should improve patient outcomes and decrease risk of harm . Various techniques and novel tools such as slotted cannulas, fluoroscopic joint entry, and over the guide wire instrumentation have been used in human hip arthroscopy in an effort to reduce IACI and instrument morbidity . To the best of the authors’ knowledge, no companies manufacture similar instrumentation or automated systems specifically designed to reduce IACI in animals.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…The results of this human study underscored the difficulties and ergonomic challenges of human stifle arthroscopy and concluded that instruments or systems to decrease these issues should improve patient outcomes and decrease risk of harm . Various techniques and novel tools such as slotted cannulas, fluoroscopic joint entry, and over the guide wire instrumentation have been used in human hip arthroscopy in an effort to reduce IACI and instrument morbidity . To the best of the authors’ knowledge, no companies manufacture similar instrumentation or automated systems specifically designed to reduce IACI in animals.…”
Section: Discussionmentioning
confidence: 97%
“…22 Various techniques and novel tools such as slotted cannulas, fluoroscopic joint entry, and over the guide wire instrumentation have been used in human hip arthroscopy in an effort to reduce IACI and instrument morbidity. 23 To the best of the authors' knowledge, no companies manufacture similar instrumentation or automated systems specifically designed to reduce IACI in animals.…”
Section: Discussionmentioning
confidence: 99%
“…Arthroscopic instrumentation systems have been developed to minimize the time and effort necessary to access the hip joint and enable orthopaedic surgeons to treat pathological findings safely and effectively [17]. Consequently, the number of arthroscopists who perform hip arthroscopy has risen.…”
Section: Discussionmentioning
confidence: 99%
“…During the arthroscopic surgical procedure, the surgeon inserts the ultrasound catheter into the hip joint using an arthroscopic portal ( Fig 1 ), sliding it into the joint through a slotted cannula. 16 The ultrasound probe is maneuvered into the areas of interest under arthroscopic control with the help of an arthroscopic hook probe by use of the same portal or another applicable portal to guide the probe.
Fig 1 (A) Plain radiographic image of right proximal femur (posterior-anterior direction).
…”
Section: Surgical Techniquementioning
confidence: 99%