2015
DOI: 10.2116/analsci.31.529
|View full text |Cite
|
Sign up to set email alerts
|

A Miniaturized Stepwise Injection Spectrophotometric Analyzer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 18 publications
(16 reference statements)
0
2
0
1
Order By: Relevance
“…[78][79][80][81][82][83] In addition, cysteine was determined based on its ability to reduce [P2Mo18O62] 6by using a stepwise injection spectrophotometric analyser, presenting a range of 9 μM -0.1 mM and a LOD of 3 μM. 84 Amperometric determination (0. /polymeric ionic liquid/rGO was also used to determine glucose, with a linear range of 2-20 mM.…”
Section: Determination Of Biomolecules and Biorelated Moleculesmentioning
confidence: 99%
“…[78][79][80][81][82][83] In addition, cysteine was determined based on its ability to reduce [P2Mo18O62] 6by using a stepwise injection spectrophotometric analyser, presenting a range of 9 μM -0.1 mM and a LOD of 3 μM. 84 Amperometric determination (0. /polymeric ionic liquid/rGO was also used to determine glucose, with a linear range of 2-20 mM.…”
Section: Determination Of Biomolecules and Biorelated Moleculesmentioning
confidence: 99%
“…In the present work, 18-molybdodiphosphate heteropoly complex of the Dawson structure is proposed as a new reagent for the spectrophotometric determination of catechins in green tea [4,19,[21][22][23][24][25][26]. The aim of the work was to develop a simple, highly reproducible, and rapid spectrophotometric procedure for determining the sum of polyphenolic compounds in green tea using 18-MPC as a reagent, which would significantly reduce the interfering effect of the reducing agents of the nonphenolic nature.…”
Section: Fig 1 Structural Formulas Of Tea Catechinsmentioning
confidence: 99%
“…En el 2014 V. Cerdà introduce la técnica de Chips miniaturizados para el análisis por inyección en flujo multijeringa (V. Cerdà, 2014). En estos últimos años los Chips han sido combinados con detección espectrofotométrica (Petrova, 2015) y espectrofluorimetría (Frizzarin, 2015) debido a características como la compacidad, la posición rígida permanente de los canales de procesamiento de muestras que aseguran la repetitividad de las manipulaciones microfluídicas y su compatibilidad con otros instrumentos.…”
Section: Introductionunclassified