2013
DOI: 10.1016/j.snb.2012.11.050
|View full text |Cite
|
Sign up to set email alerts
|

A miniaturized chemocapacitor system for the detection of volatile organic compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 22 publications
0
17
0
Order By: Relevance
“…Each IDE is coated with a different polymeric material forming an InterDigitated Capacitor (IDC). The IDC array is integrated with an electronic module that allows for the operation, control and data transfer to a PC or other unit with data storage and processing capabilities [8]. The polymers were selected on the basis of different selectivity to the vapor analytes of interest (EtOAc: ethyl acetate and water).…”
Section: Methodsmentioning
confidence: 99%
“…Each IDE is coated with a different polymeric material forming an InterDigitated Capacitor (IDC). The IDC array is integrated with an electronic module that allows for the operation, control and data transfer to a PC or other unit with data storage and processing capabilities [8]. The polymers were selected on the basis of different selectivity to the vapor analytes of interest (EtOAc: ethyl acetate and water).…”
Section: Methodsmentioning
confidence: 99%
“…In chips 2A and 2B, the thickness of the Al electrodes is approximately 120 nm and the sensing area is designed to be 0.64 mm 2 . The dimensions of the sensing areas were selected so that the capacitance before and after sorption is within the range (0-21 pF) of a miniaturized read-out electronics module [14], that allows for facile measurement of the sensor response and easy implementation in applications at the field. In Fig.…”
Section: B Sensors Fabricationmentioning
confidence: 99%
“…The interconnects end to contact pads of 0.04 mm 2 area, for facile wire bonding in a DIL package. The packaged IDE arrays are integrated with the readout electronic module that allows for the operation, control and data transfer to a PC or other unit with data storage and processing capabilities [14].…”
Section: B Sensors Fabricationmentioning
confidence: 99%
See 1 more Smart Citation
“…For the dynamic measurements a dedicated fully computer controlled laboratory set-up able to deliver flows of controlled vapor concentrations of the analytes of interest is employed [24,25]. In Fig.…”
Section: Dynamic Measurementsmentioning
confidence: 99%