2015 IEEE 13th Brazilian Power Electronics Conference and 1st Southern Power Electronics Conference (COBEP/SPEC) 2015
DOI: 10.1109/cobep.2015.7420101
|View full text |Cite
|
Sign up to set email alerts
|

A methodology of LCL filter design for grid-tied power converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…In order to select the filter parameters, grid current THDi minimization (less than 5%) as well as minimization of geometrical dimensions, power losses and costs were all taken into account. Literature analysis [18] and simulation study have shown that these criteria are best met by the filter according to Fig. 4c In addition, a thermal model of the converter was developed, in which a special thermal library of transistors was implemented, taking into account the characteristics of energy loss as a function of voltage and current.…”
Section: B Design Of Ac and DC Filtersmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to select the filter parameters, grid current THDi minimization (less than 5%) as well as minimization of geometrical dimensions, power losses and costs were all taken into account. Literature analysis [18] and simulation study have shown that these criteria are best met by the filter according to Fig. 4c In addition, a thermal model of the converter was developed, in which a special thermal library of transistors was implemented, taking into account the characteristics of energy loss as a function of voltage and current.…”
Section: B Design Of Ac and DC Filtersmentioning
confidence: 99%
“…8. Switching energy vs drain current characteristic for LSIC1M0120E0080 MOSFET [18]. (redmeasured energy for Vdc = 600V)…”
Section: A Starting the System In Inverter Modementioning
confidence: 99%
“…Many literatures presented different ideas that creating different optimization techniques to maintain the quality and stability of grids when using the VSG [11][12][13]. In addition, many literatures investigate modulation techniques such as SPWM and SVPWM to generate the PWM signals [14][15][16] in order to improve the frequency response due to synchronization process.…”
Section: Introductionmentioning
confidence: 99%
“…High power factor and low grid-connected current total harmonic distortion are common requirements for grid-connected inverters [1][2][3]. Pulse-width modulation (PWM) technology has a wide range of applications in the field of inverters, but a grid-connected inverter using PWM control technology will produce many switching frequency subharmonics, which seriously threaten the power quality and safe operation of the power grid [4][5][6]. In order to reduce the harmonic content of the grid-connected current, an appropriate grid-connected current filter must be adopted [7][8][9].…”
Section: Introductionmentioning
confidence: 99%