1995
DOI: 10.1016/0040-4039(95)00078-q
|View full text |Cite
|
Sign up to set email alerts
|

A method usingL/CMS for determination of absolute configuration of constituent amino acids in peptide --- advanced Marfey's method ---

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
102
0

Year Published

2000
2000
2014
2014

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 78 publications
(103 citation statements)
references
References 6 publications
1
102
0
Order By: Relevance
“…In order to determine the stereochemistry of the Ahp moiety, 1 was subjected to oxidation using PCC/ CH 2 Cl 2 followed by acid hydrolysis and Marfey's analysis as outlined above. The exclusive presence of L-glutamic acid in the hydrolysate showed that the Ahp moiety also possessed the L-configuration.Using the advanced Marfey's method with HPLC-MS analysis 9 we were able to demonstrate that the novel amino acid N,O-dimethylbromotyrosine also possessed an L-configuration. Direct Marfey's analysis using LC-MS identified an HPLC peak of m/z 568/570 with a retention time of 64.8 min.…”
mentioning
confidence: 99%
“…In order to determine the stereochemistry of the Ahp moiety, 1 was subjected to oxidation using PCC/ CH 2 Cl 2 followed by acid hydrolysis and Marfey's analysis as outlined above. The exclusive presence of L-glutamic acid in the hydrolysate showed that the Ahp moiety also possessed the L-configuration.Using the advanced Marfey's method with HPLC-MS analysis 9 we were able to demonstrate that the novel amino acid N,O-dimethylbromotyrosine also possessed an L-configuration. Direct Marfey's analysis using LC-MS identified an HPLC peak of m/z 568/570 with a retention time of 64.8 min.…”
mentioning
confidence: 99%
“…General 1 H and 13 C NMR spectra were recorded at 298 K on an AVANCE 500 (Bruker Biospin) spectrometer operating at 500 MHz and 125 MHz, respectively. The samples for NMR characterization were dissolved in chloroform-d or methanol-d 4 .…”
Section: Methodsmentioning
confidence: 99%
“…High-resolution mass spectra were measured with a JMS700 (JEOL) or LCT. Mass spectra for advanced Marfey's method [13] were recorded with an LCQ ion-trap mass spectrometer equipped with an electrospray ionization (ESI) probe (Thermo Electron Corporation) coupled on-line to an HP1100 system (Agilent Technology).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations