Abstract: As one of the excellent piezoelectric materials, piezoelectric ceramic has been widely used to develop a highly precise displacement measurement system, which is the key part of the scanning probe system of the high-precision measuring instrument.Based on the high-precision scanning probe system, the micro/nano structures can be easily and accurately detected by the instrument system.However, due to the limitations caused by the character of hysteresis and nonlinearity, it is difficult to further improve the p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…Reproduced with permission. [ 177 ] Copyright 2018, Chinese Physical Society. e) Fluorescence changes as ions flow across the cell membrane surface, which permits the temporal tracking of ion‐channel dynamics.…”
Section: Hybrid System Of Nv Centers and Memsmentioning
confidence: 99%
See 2 more Smart Citations
“…Reproduced with permission. [ 177 ] Copyright 2018, Chinese Physical Society. e) Fluorescence changes as ions flow across the cell membrane surface, which permits the temporal tracking of ion‐channel dynamics.…”
Section: Hybrid System Of Nv Centers and Memsmentioning
confidence: 99%
“…An example of displacement measurement is shown in Figure 9d, which demonstrates the Zeeman splitting frequency of the ESR fluorescence signal is linear with the displacement. [ 177 ] By monitoring the quantum decoherence of an NV probe in proximity to the ion channel, lipid bilayer, or surrounding aqueous environment, the cell membrane ion‐channel operation can be real‐time detected at millisecond resolution. Figure 9e shows the ion‐channel operation changes over time.…”
Section: Hybrid System Of Nv Centers and Memsmentioning
confidence: 99%
See 1 more Smart Citation
“…The magnification was about 1000 times [ 21 ]. Wang Lei et al used the high-precision sensitivity mechanism of the electron spin effect on a magnetic gradient field combined with the relationship between the magnetic gradient field and micro-displacements to study the micro-displacement measurement method based on the electron-spin-sensitive magnetic mechanism of the diamond nitrogen-vacancy color center [ 22 ].…”
Section: Introductionmentioning
confidence: 99%