2018
DOI: 10.1002/mp.13178
|View full text |Cite
|
Sign up to set email alerts
|

A method for tumor dosimetry based on hybrid planar‐SPECT/CT images and semiautomatic segmentation

Abstract: The hybrid method is found suitable for studies of tumor-absorbed doses in radionuclide therapy, provided that selection criteria regarding the visibility and overlapping activities in the planar images are applied.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 21 publications
(31 citation statements)
references
References 43 publications
(93 reference statements)
1
26
0
Order By: Relevance
“…The investigated sampling schedules depended on the simulated dosimetric approach. For the hybrid planar/SPECT method, sampling schedules comprising 2-4 planar images and one SPECT/CT measurement were investigated [14,20,[25][26][27][28]. Considering working hours [24], following 24 TPs for planar images were used: 1, 2, 3, 4, 20, 22, 24, 26, 28, 44, 48, 52, 68, 72, 76, 92, 96, 100, 116, 120, 124, 144, 168 and 192 h p.i.…”
Section: Sampling Schedulesmentioning
confidence: 99%
“…The investigated sampling schedules depended on the simulated dosimetric approach. For the hybrid planar/SPECT method, sampling schedules comprising 2-4 planar images and one SPECT/CT measurement were investigated [14,20,[25][26][27][28]. Considering working hours [24], following 24 TPs for planar images were used: 1, 2, 3, 4, 20, 22, 24, 26, 28, 44, 48, 52, 68, 72, 76, 92, 96, 100, 116, 120, 124, 144, 168 and 192 h p.i.…”
Section: Sampling Schedulesmentioning
confidence: 99%
“…The simulated time‐activity data for planar imaging were fitted with a mono‐exponential function. The TIAC was then determined with the area under the TAC scaled with the simulated activity value of the quantitative SPECT/CT measurement according toTIAC=ASPECTtSPECTAplanartSPECT·1A0·0Aplanartdt,where A SPECT is the activity value of the simulated SPECT/CT measurement, A planar is the mono‐exponential biokinetic determined by fitting the simulated planar activity data, and A 0 is the injected activity . Furthermore, the TIACs estimated without a SPECT/CT measurement, that is, only with planar imaging, were also calculated.…”
Section: Methodsmentioning
confidence: 99%
“…where A SPECT is the activity value of the simulated SPECT/ CT measurement, A planar is the mono-exponential biokinetic determined by fitting the simulated planar activity data, and A 0 is the injected activity. 6,10,11,13,25 Furthermore, the TIACs estimated without a SPECT/CT measurement, that is, only with planar imaging, were also calculated. As noise was implemented in the simulation routine, 1000 replications were performed for each sampling schedule and virtual patient, that is, 13 9 1000 TIACs were simulated for each sampling schedule.…”
Section: C Simulation Of Renal Tiacsmentioning
confidence: 99%
See 2 more Smart Citations