2005
DOI: 10.1039/b417014h
|View full text |Cite
|
Sign up to set email alerts
|

A method for the preparation of transparent mesoporous silica sol–gel monoliths containing grafted organic functional groups

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
32
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(33 citation statements)
references
References 58 publications
(5 reference statements)
1
32
0
Order By: Relevance
“…Many sensing techniques that are capable of portability are electrochemical in nature [60,61] , but some optical techniques have also been reported [25] . We have explored the use of ligand grafted sol-gel monoliths for the detection of Cu 2+ and chromate ions using optical signal transduction [23,24,26] . The determination of Cu 2+ ions is based on the formation of Cu 2+ -amine complexes between the Cu 2+ ions and amine ligands that are imprint-grafted on sol-gel monoliths [62][63][64][65] .…”
Section: Optical Metal Sensing Using Sol-gel Monolithsmentioning
confidence: 99%
See 3 more Smart Citations
“…Many sensing techniques that are capable of portability are electrochemical in nature [60,61] , but some optical techniques have also been reported [25] . We have explored the use of ligand grafted sol-gel monoliths for the detection of Cu 2+ and chromate ions using optical signal transduction [23,24,26] . The determination of Cu 2+ ions is based on the formation of Cu 2+ -amine complexes between the Cu 2+ ions and amine ligands that are imprint-grafted on sol-gel monoliths [62][63][64][65] .…”
Section: Optical Metal Sensing Using Sol-gel Monolithsmentioning
confidence: 99%
“…Our work on metal ion sensing using sol-gel monoliths removes these shortcomings by: (1) extending the pathlengths from μm-thick thin films to the ~4-5 mm; (2) coupling diffusion of the analyte to the binding sites and complexation of the analyte with the grafted ligands. The preparation of blank and amine grafted monoliths for the detection of Cu 2+ is shown in Scheme 4 [23] . These monoliths are crack-free, optically transparent, and have mesosized pores.…”
Section: Optical Metal Sensing Using Sol-gel Monolithsmentioning
confidence: 99%
See 2 more Smart Citations
“…Amounts of chemicals to obtain silica monolith named SG-M were used as described in [8], i.e. 5 ml of TMOS was mixed with 5 ml of methanol (POCH, Poland) and 2.5 ml of 0.06 M NaOH.…”
Section: Methodsmentioning
confidence: 99%