2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC) 2018
DOI: 10.1109/peac.2018.8590614
|View full text |Cite
|
Sign up to set email alerts
|

A Method for Identifying Major Disturbance Sources in a Regional Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…It should be noted that the investigation of CRs for the purposes of analyses related to PS has already been conducted in other papers. Such papers are [15][16][17][18][19][20][21]. In [15], a relationship between the injected power and the voltage quality at the node, in which installation of a new source is considered, is investigated with the use of the Pearson correlation coefficient.…”
Section: General Characteristics Of the Used Statistical Approachmentioning
confidence: 99%
See 2 more Smart Citations
“…It should be noted that the investigation of CRs for the purposes of analyses related to PS has already been conducted in other papers. Such papers are [15][16][17][18][19][20][21]. In [15], a relationship between the injected power and the voltage quality at the node, in which installation of a new source is considered, is investigated with the use of the Pearson correlation coefficient.…”
Section: General Characteristics Of the Used Statistical Approachmentioning
confidence: 99%
“…The correlation approach, assuming a partial correlation study, was also proposed to identify the disturbance source affecting power quality, which is described in [19].…”
Section: General Characteristics Of the Used Statistical Approachmentioning
confidence: 99%
See 1 more Smart Citation
“…Correlation analyses are used for solving different problems in PSs [9][10][11][12][13][14]. For instance, paper [9] deals with the study of the correlation between injected power and voltage quality at the node where a new energy source is planned for installation.…”
Section: Introductionmentioning
confidence: 99%
“…The identification of a low-frequency oscillation source is discussed in [12]. Likewise, paper [13] presents a correlation-analysis-based method for the localization of the deviation source by evaluating the correlation between the harmonic voltage of the node and the harmonic current of the deviation source. In [14], the sources of power quality disturbances are identified based on the analysis of aggregated data from a distributed measurement system with the use of Pearson's correlation coefficient.…”
Section: Introductionmentioning
confidence: 99%