2001 IEEE EMC International Symposium. Symposium Record. International Symposium on Electromagnetic Compatibility (Cat. No.01CH
DOI: 10.1109/isemc.2001.950459
|View full text |Cite
|
Sign up to set email alerts
|

A method for evaluating the shielding effectiveness of small enclosures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…The transmitting antenna is placed outside the enclosure whereas the receiving antenna is located inside the enclosure. This method is suitable for the SE evaluation of shielding room, the evaluation of small enclosures and shielding materials cannot be performed as they do not evaluate the individual properties of the shielding materials [21][22].…”
Section: Introductionmentioning
confidence: 99%
“…The transmitting antenna is placed outside the enclosure whereas the receiving antenna is located inside the enclosure. This method is suitable for the SE evaluation of shielding room, the evaluation of small enclosures and shielding materials cannot be performed as they do not evaluate the individual properties of the shielding materials [21][22].…”
Section: Introductionmentioning
confidence: 99%
“…Although [2] is being revised and a section on techniques for smaller enclosures is expected the techniques to be defined are still under discussion, possibilities include stirred mode and conducted techniques (e.g. current injection, transfer impedance) [3,4,5]. The techniques presented here are more appropriate to smaller enclosures and have the advantage over some of the other techniques that the results would be appropriate to loaded enclosures and could reduce the possibility of using over specified enclosures.…”
Section: Introductionmentioning
confidence: 99%
“…and such simulations are v e c time consuming with quite large memory requirements and also limited to enclosures with only a m a l l number of apertures. The aiithon of referenccs [2] proposed a practical method for evaluating the shielding effectiveness of sinal1 enclosiires where do not allow the use of test antennas for the ineasiirenieiit due to the limited inner space of the enclosure dimensions. Actually, in most cases, estimation aid evaluation of the shielding effectiveness are needed during the product design stage.…”
Section: Introductionmentioning