2019
DOI: 10.1109/jsen.2019.2937795
|View full text |Cite
|
Sign up to set email alerts
|

A Method Combining Measurement Tool and Numerical Simulation for Calculating Acoustic Signals of Ultrasonic Flowmeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…Boundary conditions involved in the model include the acoustic-structure interface at the inner wall, the free boundary at the outer wall and velocity input at the excitation region. The boundary conditions were described by equations (Cheeke, 2017; Sato et al , 2006; Zhao et al , 2019) listed in Table 2.…”
Section: Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…Boundary conditions involved in the model include the acoustic-structure interface at the inner wall, the free boundary at the outer wall and velocity input at the excitation region. The boundary conditions were described by equations (Cheeke, 2017; Sato et al , 2006; Zhao et al , 2019) listed in Table 2.…”
Section: Simulationmentioning
confidence: 99%
“…Among which dist( r ) and phi( r ) describe the radial distribution of velocity and phase on the surface of PZT, respectively. The functions are interpolated from experimental data based on a laser vibrometer (Zhao et al , 2019). The other function env( t ) describes the envelope of the excitation signal; it is denoted using the following exponential model (Sabatini, 1997): Where the parameters A , T and m are set to 8.042, 1.408 and 4.2, respectively, for variable t denoted in the unit of μs .…”
Section: Simulationmentioning
confidence: 99%
“…At present, there are three kinds of gas flowmeters, which are turbine, roots, and ultrasonic flowmeters. Compared with the first two flow meters, ultrasonic gas flow meters have obvious advantages in the natural gas trade measurement system due to the lack of built-in flow resistance, low-pressure loss, and high range ratio [3][4] . However, the measurement accuracy is greatly affected by the flow field distribution, the roughness of the pipeline, the structure of the upstream choke, and the degree of fluid turbulence will cause uneven velocity distribution on the channel line of the flowmeter, resulting in errors 5 .…”
Section: Introductionmentioning
confidence: 99%