2015 IEEE International Symposium on Electromagnetic Compatibility (EMC) 2015
DOI: 10.1109/isemc.2015.7256338
|View full text |Cite
|
Sign up to set email alerts
|

A measurement system for radiated transient electromagnetic interference based on general purpose instruments

Abstract: Abstract-This paper presents a measurement system intended to be used to assets the radiated electromagnetic interference (EMI) in both time and frequency domains. In order to keep the measurement setup as accessible and practical as possible, the direct measurements are recorded with a general purpose digital oscilloscope and processed with a commonly available personal computer. The measurement system was validated for radiated emissions testing using well-known, controlled transient and continuous signals e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
3

Relationship

4
3

Authors

Journals

citations
Cited by 26 publications
(19 citation statements)
references
References 15 publications
(16 reference statements)
0
19
0
Order By: Relevance
“…The DPO5104B has a 1-GHz bandwidth, a maximum sampling rate of 10 GSamples/s, 50 MSamples of memory depth, and its nominal input impedance can be set to 50 . This measurement system is more suited for radiated EMI measurement, and thus it was assessed in CISPR bands C and D. In practice, it may require additional external preamplification for increasing the sensitivity of the measurement system [12].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The DPO5104B has a 1-GHz bandwidth, a maximum sampling rate of 10 GSamples/s, 50 MSamples of memory depth, and its nominal input impedance can be set to 50 . This measurement system is more suited for radiated EMI measurement, and thus it was assessed in CISPR bands C and D. In practice, it may require additional external preamplification for increasing the sensitivity of the measurement system [12].…”
Section: Resultsmentioning
confidence: 99%
“…In general terms, a full TDEMI measurement system is described by the block diagram shown in Fig. 2 [12], [13]. For the measurement of radiated EMI, a broadband antenna shall be used, while for the measurement of conducted EMI corresponds either a current clamp or a line impedance stabilization network.…”
Section: B Full Time-domain Emi Measurement Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…3. The spectral estimation has been calculated using the Welch's periodogram and the processing techniques explained in [4] and [6]. The narrow band signal EMI cw1 at approximately 250 kHz corresponds to the AM broadcasting.…”
Section: A Decomposition Of a Synthesized Emimentioning
confidence: 99%
“…Consequently, in some cases, the standardized methods of EMI measurement and evaluation are not completely suitable, insufficient or might require an enormous amount of time to provide reliable measurement results [3], [4]. Currently, the fast Fourier transform-based EMI test receivers and real-time spectrum analyzers have time-scan measurement capabilities that overcome many of the limitations of the stepped frequency scan in the EMI receivers.…”
mentioning
confidence: 99%