A measurement setup for direct 17O MRI at 7 T

Abstract: An efficient breathing system was designed for direct 17 O MRI to perform oxygen metabolism studies of the human brain. The breathing system consists of a demand oxygen delivery device for 17 O 2 supply and a custom-built rebreathing circuit with pneumatic switching valve. To efficiently deliver the 17 O gas to the alveoli of the lungs, the system applies short gas pulses upon an inspiration trigger via a nasal cannula. During and after 17 O 2 administration, the exhaled gas volumes are stored and filtered in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
90
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 48 publications
(96 citation statements)
references
References 20 publications
(63 reference statements)
5
90
1
Order By: Relevance
“…Thus, it is of high clinical interest to map oxygen metabolism in clinical routine. With the recent implementation of 17 O MRI (26,27,(30)(31)(32)(33), clinical CMRO 2 quantification and oxygen metabolism mapping might become feasible; however, the different parameters in the numerical description of the oxygen uptake are often not identifiable from time-resolved measurements alone. In this study, the PL method was used to identify those parameters in the CMRO 2 quantification model that require prior knowledge for a unique identification.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Thus, it is of high clinical interest to map oxygen metabolism in clinical routine. With the recent implementation of 17 O MRI (26,27,(30)(31)(32)(33), clinical CMRO 2 quantification and oxygen metabolism mapping might become feasible; however, the different parameters in the numerical description of the oxygen uptake are often not identifiable from time-resolved measurements alone. In this study, the PL method was used to identify those parameters in the CMRO 2 quantification model that require prior knowledge for a unique identification.…”
Section: Discussionmentioning
confidence: 99%
“…If CMRO 2 was non-identifiable, a DODS was fixed to 0.27/ 0.31 (for Exp1/Exp2) based on the estimated amount of 17 O 2 inhaled with a single DODS pulse as in (27,32) 2 , which include the optimum CMRO 2 value, were calculated using Equation [5] for the confidence level CL ¼ 0.33 and were used to present the calculated CMRO 2 values. It is worth noting that in this study the CMRO 2 values were presented for each dataset separately, and not as the range among several MR examinations.…”
Section: Model Analysis For Cmro 2 Quantificationmentioning
confidence: 99%
See 3 more Smart Citations