2013
DOI: 10.1371/journal.pone.0068369
|View full text |Cite
|
Sign up to set email alerts
|

A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection

Abstract: Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
74
1
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 54 publications
(78 citation statements)
references
References 30 publications
2
74
1
1
Order By: Relevance
“…6 A 67 bp amplicon of the IS6110 sequence was amplified using 0.2 µM forward primer (5′ ACC AGC ACC TAA CCG GCT GTG G 3′) and 0.2 µM reverse primer (5′ CAT CGT GGA AGC GAC CCG CCA G 3′). 12 Chamber 1 ( Fig. 1) consisted of 100 µL TE buffer, 5 µL IS6110 DNA at a concentration of 10 6 copies/µL, 300 µL binding buffer (4M guanidine thiocyanate, 25 mM sodium citrate pH 7.0), and 20 µL Dynabeads MyOne Silane magnetic beads (~6 × 10 8 beads; Life Technologies 37002D, Carlsbad, CA).…”
Section: Tubing For Extraction and Pcr Amplification Of Tuberculosis mentioning
confidence: 99%
“…6 A 67 bp amplicon of the IS6110 sequence was amplified using 0.2 µM forward primer (5′ ACC AGC ACC TAA CCG GCT GTG G 3′) and 0.2 µM reverse primer (5′ CAT CGT GGA AGC GAC CCG CCA G 3′). 12 Chamber 1 ( Fig. 1) consisted of 100 µL TE buffer, 5 µL IS6110 DNA at a concentration of 10 6 copies/µL, 300 µL binding buffer (4M guanidine thiocyanate, 25 mM sodium citrate pH 7.0), and 20 µL Dynabeads MyOne Silane magnetic beads (~6 × 10 8 beads; Life Technologies 37002D, Carlsbad, CA).…”
Section: Tubing For Extraction and Pcr Amplification Of Tuberculosis mentioning
confidence: 99%
“…The usefulness of magnetic beads in the microfluidics has already been reported in the bioassay field. [9][10][11][12][13] Magnetic beads are easily controlled from the outside of the camber, and in microfluidics, they are indirectly transferred between several reagents for lysing, extracting, and washing. We also used a combination of superparamagnetic beads and magnetic force for purifying nucleic acids.…”
Section: Introductionmentioning
confidence: 99%
“…9 Several bioassays have also already demonstrated the utility of magnetic beads in microfluidics. [10][11][12][13] Connection of such a cartridge extraction and purification system 9 to our novel droplet-real-time-PCR system 14 allows PCR tests to be performed simply in high-throughput assays by simple pouring of the sample into the cartridge. This system can eliminate the problems associated with delivering materials such as nucleic acids, proteins, and cells that may adhere to sample tubes and allows liquid handling of all processes.…”
Section: Introductionmentioning
confidence: 99%