A Low-Cost System for Seismocardiography-Based Cardiac Triggering: A Practical Solution for Cardiovascular Magnetic Resonance Imaging at 3 Tesla

Abstract: This study describes a pilot clinical validation of a new low-cost system for the continuous monitoring of the human body's cardiorespiratory activities within the magnetic resonance examination area. This study primarily focuses on monitoring cardiac activity and the related cardiac triggering. The patented system tested by the authors is based on seismocardiography (SCG). The study was conducted on 18 subjects on a Siemens Prisma 3T MR scanner. Standard anatomical and diffusion sequences were used to test ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 13 publications
(24 citation statements)
references
References 71 publications
(96 reference statements)
1
23
0
Order By: Relevance
“…In addition to the delay of the BCG signal in comparison with the reference ECG signal, it is also necessary to take into account the delay in transmission caused the propagation of the pressure change through the tube. The issue of delays between the ECG and the BCG, or the SCG, is discussed in detail in study [36]. In general, any pressure sensor can be used to measure the pressure inside the pneumatic system.…”
Section: A Sensor Embodimentmentioning
confidence: 99%
See 3 more Smart Citations
“…In addition to the delay of the BCG signal in comparison with the reference ECG signal, it is also necessary to take into account the delay in transmission caused the propagation of the pressure change through the tube. The issue of delays between the ECG and the BCG, or the SCG, is discussed in detail in study [36]. In general, any pressure sensor can be used to measure the pressure inside the pneumatic system.…”
Section: A Sensor Embodimentmentioning
confidence: 99%
“…The application displays the BCG waveform measured, the peaks detected and the triggers generated in real-time and allows the user to configure the peak detection algorithm and the triggering delay defined. The hardware and software setup utilized was identical with the ones used in our previous research [36]. A complete block diagram of the system with the detailed description of the peak detection and the trigger generation logic implemented in FPGA is shown in Fig.…”
Section: B Description Of the Measuring Sw And Hwmentioning
confidence: 99%
See 2 more Smart Citations
“…It would also be good to combine bioelectrical impedance spectroscopy with other measurement methods such as ECG or EEG [40]- [42]. Except measuring body structure, it would be also possible to detect stress or some serious conditions [10], [41].…”
Section: A Further Research Plansmentioning