1996
DOI: 10.1016/s0969-8043(96)00097-8
|View full text |Cite
|
Sign up to set email alerts
|

A low background counting facility at laboratori nazionali del Gran Sasso

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
108
0
2

Year Published

1998
1998
2012
2012

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 112 publications
(112 citation statements)
references
References 4 publications
2
108
0
2
Order By: Relevance
“…Most of the bulk material in the general construction were screened by this method, setting up an extensive database on bulk material radiopurity. 61,62 Inductively coupled mass spectrometry (ICPMS) is applicable to U,Th detection with a typical sensitivity of 10 -12 g/g, rising however to 10 -15 g/g for water in particular. 63 This technique has been applied to assay water samples, nylon material (after concentration by chemical ashing or digestion) and LS material (after concentration by water extraction).…”
Section: Radiopurity Of Detector Materialsmentioning
confidence: 99%
“…Most of the bulk material in the general construction were screened by this method, setting up an extensive database on bulk material radiopurity. 61,62 Inductively coupled mass spectrometry (ICPMS) is applicable to U,Th detection with a typical sensitivity of 10 -12 g/g, rising however to 10 -15 g/g for water in particular. 63 This technique has been applied to assay water samples, nylon material (after concentration by chemical ashing or digestion) and LS material (after concentration by water extraction).…”
Section: Radiopurity Of Detector Materialsmentioning
confidence: 99%
“…Moreover, the electrical conductivity (EC), oxidation-reduction potential (ORP), and pH were determined with common laboratory equipment. As ICP-MS cannot be used to analyze the radioisotopes following uranium in the natural radioactive decay chain due to their extremely small concentration, some samples were filtered and analyzed by means of gamma-ray spectroscopy with high purity germanium (HPGe) detectors at the STELLA low background facility of the LNGS [18]. Using this technique the gamma active radionuclides in the uranium chain can be assessed, in particular the subchain of radium.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…In order to reduce the systematic error coming from the uncertainty on the angular distribution, a lead collimator was positioned inside the target chamber to collect mostly -rays emitted at 55°, where the contribution of the second Legendre polynomial vanishes. After each run, the calorimeter cap was dismounted and its activity counted off-line with a 125% HPGe detector, shielded by 15 cm of lead and 10 cm of copper on each side and placed in the low activity laboratory of LNGS [23].…”
Section: Be Reactionmentioning
confidence: 99%