2009
DOI: 10.1016/j.aca.2009.10.012
|View full text |Cite
|
Sign up to set email alerts
|

A liquid chromatography–tandem mass spectrometry confirmatory assay for the simultaneous determination of several tetracyclines in milk considering keto–enol tautomerism and epimerization phenomena

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0
1

Year Published

2010
2010
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 41 publications
(13 citation statements)
references
References 44 publications
1
11
0
1
Order By: Relevance
“…USEPA Method 1694 guidelines establishes that any chromatographic gradient may be applied for the separation of the pharmaceutical compounds as long as the last eluting peak has a retention time greater than that obtained in the standard USEPA method [19] [24]. Gradient elution for chromatographic separation of tetracyclines was the same described by Spisso et al [3]. For sulfonamide separation, another gradient was developed based on that employed for tetracyclines, due to the physicochemical similarities.…”
Section: Lc Methods Developmentmentioning
confidence: 99%
See 2 more Smart Citations
“…USEPA Method 1694 guidelines establishes that any chromatographic gradient may be applied for the separation of the pharmaceutical compounds as long as the last eluting peak has a retention time greater than that obtained in the standard USEPA method [19] [24]. Gradient elution for chromatographic separation of tetracyclines was the same described by Spisso et al [3]. For sulfonamide separation, another gradient was developed based on that employed for tetracyclines, due to the physicochemical similarities.…”
Section: Lc Methods Developmentmentioning
confidence: 99%
“…Multiple Reaction Monitoring (MRM) experiments for tetracycline analysis in electrospray positive-ion mode (ESI+) were described by Spisso et al [3] and the employed conditions are listed in Table 3.…”
Section: Lc/ms-ms Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation
“…[12][13][14][15] Conhecer a concentração de um tautômero não necessariamente satisfaz às necessidades dos ensaios de controle de qualidade, visto que na legislação não há informação sobre as concentrações limites para cada tautômero, nem sobre as proporções entre eles.…”
Section: Introductionunclassified
“…22 Due to its high sensitivity and selectivity, HPLC coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) 23,24 is becoming more commonly used in the analysis of TCs in very complex samples such as milk, waste water and animal tissues. MS detection with high sensitivity and accurate quantication is the method selected in this study.…”
Section: Introductionmentioning
confidence: 99%