2019
DOI: 10.1016/j.cca.2018.11.036
|View full text |Cite
|
Sign up to set email alerts
|

A light-initiated chemiluminescent assay for rapid quantitation of allergen-specific IgG4 in clinical samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 37 publications
0
12
0
Order By: Relevance
“…A bead-based light-initiated chemiluminescent assay (LICA) system was demonstrated in our previous studies to determine serum egg component-sIgE and sIgG4 profiles. LICA has been proven to have excellent analytical performances and a good correlation with Phadia Immu-noCAP tests in sIgE measurement [16,17]. Yet, only a limited profile of allergy tests has been introduced in our country; LICA could be a reliable complement in allergy screening and diagnosis.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A bead-based light-initiated chemiluminescent assay (LICA) system was demonstrated in our previous studies to determine serum egg component-sIgE and sIgG4 profiles. LICA has been proven to have excellent analytical performances and a good correlation with Phadia Immu-noCAP tests in sIgE measurement [16,17]. Yet, only a limited profile of allergy tests has been introduced in our country; LICA could be a reliable complement in allergy screening and diagnosis.…”
Section: Discussionmentioning
confidence: 99%
“…Samples with sIgE to egg white ≥ 0:35 kU A /L were defined as positive. [16,17]. The results of sIgE and sIgG4 were calculated as relative light units (RLU).…”
Section: Determination Of Total Ige and Egg-specific Ige Levelsmentioning
confidence: 99%
“…The levels of sige and sigG 4 to rPen a 1 as well as its peptides were measured using a light-initiated chemiluminescent assay (lica) carried out as previously described (34,35). lica is based on the formation of nanoparticle pairs and luminescence oxygen channeling immunoassay technology (36,37).…”
Section: Preparation Of Biotinylated Recombinant Pen a 1 Ez-linkmentioning
confidence: 99%
“…lica is based on the formation of nanoparticle pairs and luminescence oxygen channeling immunoassay technology (36,37). Studies have shown that this new method possesses excellent performance characteristics with high sensitivity, broad analytical range and rapid turnaround cycles and is suitable for immunodetection of allergen sige and sigG 4 (34,35 well and incubated at 37˚C for 30 min with mild agitation. Subsequently, 150 µl streptavidin-coated sensibeads (Beyond Biotech, co., ltd.) were added.…”
Section: Preparation Of Biotinylated Recombinant Pen a 1 Ez-linkmentioning
confidence: 99%
“…To the best of our knowledge, there has been no report on the LICA-based detection of inhaled allergen-sIgE till date [6][7][8][9][10][11][12][13]. Moreover, the Artemisia pollen is the most widespread outdoor allergen throughout China, which can cause allergic rhinitis, asthma, and/or both [14].…”
Section: Introductionmentioning
confidence: 99%