A laser-induced graphene-based flexible and all-carbon organic electrochemical transistor

Abstract: As next-generation bioelectronic devices, organic electrochemical transistors (OECTs) have attracted great interest in health monitoring and early diagnosis because of their high sensitivity, easy integration, high flexibility, light weight, and...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
15
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 72 publications
1
15
0
Order By: Relevance
“…Fitting the slope of the linear fit to this data yields the materials' figure of merit, mobility volumetric capacitance product (μC*), and is the most common characterization technique for OECTs in the literature, 35,54 despite recent concerns that it overestimates mobility. 55 Representative transfer and output curves of each formulation are shown in Figures S12 and S13, respectively. For accurate μC* determination, determination of thickness is essential.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Fitting the slope of the linear fit to this data yields the materials' figure of merit, mobility volumetric capacitance product (μC*), and is the most common characterization technique for OECTs in the literature, 35,54 despite recent concerns that it overestimates mobility. 55 Representative transfer and output curves of each formulation are shown in Figures S12 and S13, respectively. For accurate μC* determination, determination of thickness is essential.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Organic electrochemical transistors (OECTs) have attracted great attention in the fields of biosensing and bioelectronics because of their simple structure, low working voltage (<1 V), and high biocompatibility. OECTs have been used not only for the detection of biomarkers, such as glucose, dopamine, , and DNA, but also for pressure sensing and artificial synapses. Many measurements have been used to evaluate the performance of OECTs. , The output curve measures the output current from source to drain electrodes at a fixed gate voltage while varying the source-drain voltage. The transfer curve measures the current from the source to drain electrodes at a fixed source-drain voltage while varying the gate voltage.…”
Section: Introductionmentioning
confidence: 99%
“…Improving the transconductance is crucial to realizing high-performance OECTs. 8–10 Two types of strategies are used to improve the transconductance of OECTs. One is geometry optimization of the channel layer.…”
Section: Introductionmentioning