2023
DOI: 10.1039/d3ja00053b
|View full text |Cite
|
Sign up to set email alerts
|

A laboratory X-ray emission spectrometer for phosphorus Kα and Kβ study of air-sensitive samples

Abstract: The analytical chemistry of phosphorus-containing materials is often impeded by the long measurement times and relatively large sample masses needed for 31P NMR spectroscopy, by the scarcity and access limitations...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 46 publications
0
4
0
Order By: Relevance
“…In a recent detailed study, in which 5 nm Ni 2 P nanoparticles were synthesized under fully inert conditions and analyzed by P Kα X-ray emission spectroscopy (a bulk technique) after controlled air exposure, Seidler and co-workers demonstrated nearly complete oxidation to nickel phosphate after 1 week of air exposure. [37] The air-stability of Ni 2 P/Al 2 O 3 1-step , on the other hand, more closely resembles that of Pd/Al 2 O 3 . [27a] Crucially, thermal hydrogenation of nickel oxide and nickel phosphate, the common oxidation products of Ni 2 P, generally requires temperatures of ~450 °C and ~700 °C.…”
Section: Forschungsartikelmentioning
confidence: 99%
“…In a recent detailed study, in which 5 nm Ni 2 P nanoparticles were synthesized under fully inert conditions and analyzed by P Kα X-ray emission spectroscopy (a bulk technique) after controlled air exposure, Seidler and co-workers demonstrated nearly complete oxidation to nickel phosphate after 1 week of air exposure. [37] The air-stability of Ni 2 P/Al 2 O 3 1-step , on the other hand, more closely resembles that of Pd/Al 2 O 3 . [27a] Crucially, thermal hydrogenation of nickel oxide and nickel phosphate, the common oxidation products of Ni 2 P, generally requires temperatures of ~450 °C and ~700 °C.…”
Section: Forschungsartikelmentioning
confidence: 99%
“…X-ray Emission Spectroscopy. P Kα and Kβ XES measurements were performed on a laboratory spectrometer described in Abramson et al, 72 with a design similar to that of Holden et al, 73 and where the methodology of Stein et al 18 was used for estimating the oxidation state. The spectrometer is set up in a N 2 -filled glovebox and uses a low-power, unfocused X-ray tube (Varex VF-80, 100 W) to illuminate the sample, whose emitted X-rays are analyzed simultaneously by two 10 cm radius of curvature cylindrical crystal analyzer and coupled to homemade complementary metal oxide semiconductor (CMOS) direct-exposure color X-ray cameras.…”
Section: ■ Conclusionmentioning
confidence: 99%
“…The two multiplexed spectrometers are tuned to the P Kα and Kβ emission energies, respectively. Data collection followed the methodology from Abramson et al 72 InP QD samples were drop-cast onto Si wafer with a spot size of ∼5 mm diameter. The Kα emission spectra were analyzed using linear combination fitting with the nonlinear leastsquares fitting Python package LMFIT.36 (described in more detail in Stein et al 18 ).…”
Section: ■ Conclusionmentioning
confidence: 99%
“…Access to XES at synchrotron facilities in the tender X-ray region can be very limited and highly competitive (Mori et al, 2010;Rehanek et al, 2018;Butorin et al, 2018;Abraham et al, 2019;Rovezzi et al, 2020;Qureshi et al, 2021). Moreover, the availability of non-synchrotron based instruments for such experiments is also quite limited (Petric & Kavc ˇic ˇ, 2016;Malzer et al, 2018;Holden et al, 2017Holden et al, , 2018Abramson et al, 2023).…”
Section: Introductionmentioning
confidence: 99%