1989
DOI: 10.1007/bf02636193
|View full text |Cite
|
Sign up to set email alerts
|

A justification for using a whole‐grain oven method to determine soybean moisture content

Abstract: Three air‐oven moisture methods, AOCS Ac 2‐41, AACC 44‐18 and the official USDA method, were compared on 20 samples of 1987 crop soybeans. The AOCS method is a whole‐grain method, the other two are two‐stage, ground‐grain methods. The average difference between the AOCS and USDA methods was 0.04 percentage points with a standard deviation of 0.18 points. The AOCS method can be used interchangeably with the USDA method for calibration of moisture devices. The AACC method averaged 0.15 and 0.19 points higher tha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1991
1991
2021
2021

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…The moisture content was determined according to the AACC method (Hartwig & Hurburgh, 1989). Water activity was measured using a water activity meter (Model AQUALAB SERIES 4, METER Group, USA).…”
Section: Determination Of Moisture Content Water Activity and Water Statementioning
confidence: 99%
“…The moisture content was determined according to the AACC method (Hartwig & Hurburgh, 1989). Water activity was measured using a water activity meter (Model AQUALAB SERIES 4, METER Group, USA).…”
Section: Determination Of Moisture Content Water Activity and Water Statementioning
confidence: 99%
“…• Thousand-seed weight, TGW, g (weight of counted seeds), counted by hand. At the completion of a set of tests, triplicate whole-seed oven moistures (AOCS, 1987;Hartwig and Hurburgh, 1990) also were run.…”
Section: Samples -Cornmentioning
confidence: 99%
“…After 10 days, the beans were assumed to be at equilibrium. Oven moistures of three whole-grain samples, approximately 10 g each, were averaged to obtain the moisture content of the subsample (Hartwig and Hurburgh, 1989). The final range of moistures is shown in Table 2.…”
Section: Laboratory Analysismentioning
confidence: 99%
“…Each bean was weighed to the nearest 0.0001 g, and its spectral absorbance was immediately recorded. The bean was then dried in an air-oven at 130° C (266° F) for 3 h and (Hartwig and Hurburgh, 1989). The 601-point spectral curves were smoothed by using a 5-point (1 nm gap width) moving average to reduce the influence of noise in the spectra: plane separating the cotyledons was used to estimate the optical pathlength (t).…”
Section: Laboratory Analysismentioning
confidence: 99%