2017
DOI: 10.1007/s00604-017-2484-9
|View full text |Cite
|
Sign up to set email alerts
|

A hyperbranched polyamidoamine dendrimer grafted onto magnetized graphene oxide as a sorbent for the extraction of synthetic dyes from foodstuff

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(10 citation statements)
references
References 30 publications
1
8
0
Order By: Relevance
“…The peak at 1600 cm −1 corresponds to C = C stretching mode. The bands in the 998– 1410 cm −1 region are ascribed to C–N, C = N stretching and rotation vibration in the network . The bands in the 440–858 cm −1 are associated to the bending vibration modes of the C–NH 2 groups.…”
Section: Resultsmentioning
confidence: 97%
“…The peak at 1600 cm −1 corresponds to C = C stretching mode. The bands in the 998– 1410 cm −1 region are ascribed to C–N, C = N stretching and rotation vibration in the network . The bands in the 440–858 cm −1 are associated to the bending vibration modes of the C–NH 2 groups.…”
Section: Resultsmentioning
confidence: 97%
“…Applying fast chromatography approach of advanced technology of column packing material provided reduction of back pressure and fastening the separation. We achieved significant shortening of analysis of eight colorants in comparison with previously published methods [17,18,19,20,23]. One work published separation of eight colorants using core-shell column in time less than six min [29].…”
Section: Discussionmentioning
confidence: 99%
“…After appropriate pre-extraction and clean-up, it is a very common and versatile method for simultaneous determination of numerous colourings in complex food matrices. Despite of some recent interesting applications [16], thin-layer chromatography has been almost superseded by liquid chromatography (HPLC-DAD) [17,18,19,20,21,22,23], similarly very fast and simple method of sequential injection chromatography has been reported [24]. Nowadays, in many cases mass spectrometry detection with mass confirmation has been involved [25,26].…”
Section: Introductionmentioning
confidence: 99%
“…The construction of hyperbranched PAMAM on magnetic support was achieved by repeating two steps: [33] (1) formation of methyl ester surface groups derived from the Michael addition of MA to the surface amino groups; and (2) amidation reaction of the resulting ester moieties with EDA. The general procedure for the Michael addition of MA to the surface amino groups was as follows: a mixture of the amine functionalized MNP (0.1 g) and MA (5 mmol) was dispersed in 5 ml of ethanol, and the resulting mixture was allowed to reflux for 12 hr under vigorous stirring under the protection of N 2 .…”
Section: Preparation Of Pamam Dendrimer-coated Fe 3 O 4 Nanoparticlmentioning
confidence: 99%