2016
DOI: 10.1002/mrm.26401
|View full text |Cite
|
Sign up to set email alerts
|

A hybrid multibreath wash-in wash-out lung function quantification scheme in human subjects using hyperpolarized3He MRI for simultaneous assessment of specific ventilation, alveolar oxygen tension, oxygen uptake, and air trapping

Abstract: Purpose To present a method for simultaneous acquisition of alveolar oxygen tension (PAO2), specific ventilation (SV), and apparent diffusion coefficient (ADC) of hyperpolarized (HP) gas in the human lung, allowing reinterpretation of the PAO2 and SV maps to produce a map of oxygen uptake (R). Method An imaging scheme was designed with a series of identical normoxic HP gas wash-in breaths to measure ADC, SV, PAO2 and R in less than 2 minutes. Signal dynamics was fit to an iterative recursive model that regio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
51
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(56 citation statements)
references
References 55 publications
(105 reference statements)
5
51
0
Order By: Relevance
“…Statistically significant correlations were observed for all evaluated lung function test parameters compared with median and interquartile range of 19 F washout parameters. An inverse linear correlation of median number of breaths (r = 20.82; P , .0001) and median washout times (r = 20.77; P , .0001) with percentage predicted of forced expiratory volume in 1 second (FEV 1 ) was observed; correspondingly median FV (r = 0.86; P , .0001) correlated positively with percentage predicted FEV 1 .…”
Section: Resultsmentioning
confidence: 86%
See 4 more Smart Citations
“…Statistically significant correlations were observed for all evaluated lung function test parameters compared with median and interquartile range of 19 F washout parameters. An inverse linear correlation of median number of breaths (r = 20.82; P , .0001) and median washout times (r = 20.77; P , .0001) with percentage predicted of forced expiratory volume in 1 second (FEV 1 ) was observed; correspondingly median FV (r = 0.86; P , .0001) correlated positively with percentage predicted FEV 1 .…”
Section: Resultsmentioning
confidence: 86%
“…Quantification of regional lung ventilation by using dynamic 19 F gas washout MR imaging in free breathing is feasible at 1.5 T even in obstructed lung segments. F gas mixture can be continuously inhaled over several minutes without any notable adverse effects (22)(23)(24).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations