A historical perspective of pacemaker infections: 40-years single-centre experience

Abstract: Continuous assimilation of guidelines for pacemaker infection improved the outcome over time: complete extraction of the infected device seems to be highly desirable. A one-stage exchange increased the risk of recurrent device infection and should probably be avoided, but complete extraction seems to be more important than timing.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
11
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 25 publications
2
11
0
Order By: Relevance
“…Interestingly, in the Netherlands, due to lower numbers of intravenous drug users, the frequency of right-sided endocarditis has notably dropped [9]. At the same time, the worldwide rise in methicillin-resistant Staphylococcus aureus (MRSA) has augmented MRSA-related IE [1014]. Furthermore, there has been a substantial increase in the use of prosthetic heart valves, both mechanical and biological [15].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Interestingly, in the Netherlands, due to lower numbers of intravenous drug users, the frequency of right-sided endocarditis has notably dropped [9]. At the same time, the worldwide rise in methicillin-resistant Staphylococcus aureus (MRSA) has augmented MRSA-related IE [1014]. Furthermore, there has been a substantial increase in the use of prosthetic heart valves, both mechanical and biological [15].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, there has been a substantial increase in the use of prosthetic heart valves, both mechanical and biological [15]. Also, the increased use of devices such as pacemakers and implantable cardiac defibrillators is posing new challenges [10]. …”
Section: Introductionmentioning
confidence: 99%
“…For this reason, the guidelines of the AHA/ACC/HRS recommend the removal of all system components (generator and catheters) . Although extraction is the elective treatment in cases of infections of CIEDs, this procedure involves various risks, some of which are serious or even fatal . Although with the advent of laser extraction systems the procedures have been simplified and a success rate of 98% is reported, these data reflect however the situation of very experienced centers with high volumes of procedures .…”
Section: Discussionmentioning
confidence: 99%
“…A closed system of antibiotic irrigation was then applied to the patients during the 72 h after the procedure, and oral antibiotics were prescribed after discharge. Patients were all followed for at least 1 year without evidence of recurrence despite three patients died due to causes not related to device infection . Another example is a recent case report from Schaller et al, which involved a young patient.…”
Section: Discussionmentioning
confidence: 99%
“…Some of the common reasons for noncapture include lead dislodgement or break in circuit, lead failure, and inflammation and fibrosis at the electrode‐myocardium interface leading to a higher threshold for stimulation [1]. The usual treatment of a pocket infection involves removing the entire infected pacing system (pulse generator and leads); this reduces the risk of reinfection by 75% [2].…”
Section: Introductionmentioning
confidence: 99%