A histopathological tool for quantification of biomarkers with sub-cellular resolution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 42 publications
0
9
0
Order By: Relevance
“…Inter-platform variability between different DIA platforms may be expected as tissue morphology, cellular features, and staining patterns are handled differently depending on the platform’s algorithm [ 15 , 20 ]. In clinical practice, this could lead to inconsistency of Ki67 scores when different platforms are used to perform DIA.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Inter-platform variability between different DIA platforms may be expected as tissue morphology, cellular features, and staining patterns are handled differently depending on the platform’s algorithm [ 15 , 20 ]. In clinical practice, this could lead to inconsistency of Ki67 scores when different platforms are used to perform DIA.…”
Section: Discussionmentioning
confidence: 99%
“…Studies comparing manual scoring and DIA have used different platforms by various vendors, which have unique image analysis algorithms to determine Ki67 proliferation index [ 12 17 ]. As these algorithms have different approaches to classify tissue and cellular components, inter-platform variability may be expected [ 15 , 20 ]. To the best of our knowledge, all studies up to this date have implemented only one DIA platform per study and therefore have not examined inter-platform agreement.…”
Section: Introductionmentioning
confidence: 99%
“…These have previously been validated on data from multiple sites comprising thousands of tumor samples to ensure that the variance that DIA contributes is kept at a minimum 40 (see specific statistics on reproducibility with Visiopharm integrator system for each tested biomarker in Supplementary Data).…”
Section: Discussionmentioning
confidence: 99%
“…Thus, only cells that express cytokeratin are eligible for detection of positivity or negativity for the respective biomarker. Individual applications for each biomarker then run the scoring of positive and negative cells itself, with subcellular resolution 40 ( Figure 1). Excellent reproducibility with this and similar systems has been shown previously [41][42][43][44][45] (see specific statistics on reproducibility with the Visiopharm integrator system for each tested biomarker in Supplementary Data).…”
Section: Digital Image Analysismentioning
confidence: 99%
“…For a more general system dealing with various histologically stained image data, Kårsnäs et al. [KSD*15] provided a comprehensive software tool for extracting and quantifying sub‐cellular data. They especially account for biological and staining‐induced variations.…”