2010
DOI: 10.1007/s00216-010-3506-1
|View full text |Cite
|
Sign up to set email alerts
|

A highly sensitive caffeine immunoassay based on a monoclonal antibody

Abstract: A new immunoassay has been developed based on a commercially available anti-caffeine monoclonal antibody and a de novo synthesized tracer, using horseradish peroxidase and UV-visible detection. Caffeine, which is frequently found in surface waters, can be quantified with a relative error lower than 20% for concentrations above 0.025 microg L(-1) (limit of quantitation, direct analysis). The limit of detection is 0.001 microg L(-1) and can be reduced by solid-phase extraction (SPE). Moreover, with minor adaptat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
38
0
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 44 publications
(42 citation statements)
references
References 70 publications
3
38
0
1
Order By: Relevance
“…A C18 reversed-phase column, 250 mm  2.1 mm, 5 mm (Phen, UltraSep ES, SepServ, Berlin, Germany) was used and the ionization performed in electrospray positive ion mode (ESIþ). The chromatographic method was previously described in detail (Carvalho et al 2010).…”
Section: Lc-ms/ms Reference Methods For Caffeine Determinationmentioning
confidence: 99%
See 3 more Smart Citations
“…A C18 reversed-phase column, 250 mm  2.1 mm, 5 mm (Phen, UltraSep ES, SepServ, Berlin, Germany) was used and the ionization performed in electrospray positive ion mode (ESIþ). The chromatographic method was previously described in detail (Carvalho et al 2010).…”
Section: Lc-ms/ms Reference Methods For Caffeine Determinationmentioning
confidence: 99%
“…The cross-reactivity was calculated as the ratio of mass concentrations at the inflection points (midpoints, parameter C in the 4-parameters sigmoidal curve % half maximum inhibitory concentration, IC50) of the corresponding calibration curves and expressed in percent relative to the caffeine midpoint, as previously described (Bahlmann et al 2009;Carvalho et al 2010). …”
Section: Cross-reactivity Determinationmentioning
confidence: 99%
See 2 more Smart Citations
“…Immunoassays have been widely applied in other areas of science, in particular clinical analyses [56]. However, despite the first studies on using immunoassays to detect pharmaceutical in surface waters showing up around 10 years ago [57] for the detection on Diclofenac, they have received limited further attention [58][59][60]. This may be due Copyright © 2013 SciRes.…”
Section: The Challenge Of Nitrate Source Determinationmentioning
confidence: 99%