2019
DOI: 10.1088/1555-6611/ab5797
|View full text |Cite
|
Sign up to set email alerts
|

A highly sensitive and compact plasmonic ring nano-biosensor for monitoring glucose concentration

Abstract: In this study, a new plasmonic biosensor is proposed, which is highly sensitive with a compact structure, based on numerical methods for glucose concentration monitoring in different samples. The biosensor is based on a metal-insulator-metal waveguide and a ring resonator, and the calculated results are analyzed. The glucose biosensor operation is based on the refractive index of the glucose solution in the structure. In this study, to improve the sensitivity of the biosensor, the effect of the inner radius si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…Due to the ability of efficient and precise detection of the RI, it can be widely used in the biomedical field like in the concentration detection of glucose aqueous solution and detection of single waterborne bacteria. 31,32…”
Section: Design and Simulation Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Due to the ability of efficient and precise detection of the RI, it can be widely used in the biomedical field like in the concentration detection of glucose aqueous solution and detection of single waterborne bacteria. 31,32…”
Section: Design and Simulation Resultsmentioning
confidence: 99%
“…Based on eqn (15), the APs forming based on the CPA of the OBM at different fs are calculated. When the value of Dj 2 is 01, a sharp AP forms at about f = 108.92 THz in the case of n D = 1.66.…”
Section: Production Of Sharp Apsmentioning
confidence: 99%
See 2 more Smart Citations
“…In recent years, various multi-port output beam splitters have been proposed, such as even-port beam splitter [6][7][8][9], odd-port output beam splitter [10][11][12], and polarization selective beam splitter [13,14]. Among them, the three-port beam splitter has the features of simple structure and large manufacturing tolerance, so it is widely used in pulse detection [15], sensors [16][17][18][19][20][21], signal processing [22][23][24], and photonic crystal fabrication [25,26]. Therefore, it is necessary to propose an efficient three-port diffraction beam splitter.…”
Section: Introductionmentioning
confidence: 99%