2019
DOI: 10.1038/s41598-019-54885-6
|View full text |Cite
|
Sign up to set email alerts
|

A highly-selective chloride microelectrode based on a mercuracarborand anion carrier

Abstract: The chloride gradient plays an important role in regulating cell volume, membrane potential, pH, secretion, and the reversal potential of inhibitory glycine and GABAA receptors. Measurement of intracellular chloride activity, , using liquid membrane ion-selective microelectrodes (ISM), however, has been limited by the physiochemical properties of Cl− ionophores which have caused poor stability, drift, sluggish response times, and interference from other biologically relevant anions. Most importantly, intracell… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 44 publications
0
9
0
Order By: Relevance
“…By 1200-APs in SM-CD ( Figure 2A ), [Na + ] I rises almost 25 mM above steady-state whereas post-one-AP, [Na + ] I increases <0.05 mM. For contraction-inhibited SMFs (current or voltage-clamped), a new 4-microelectrode technique enables simultaneous monitoring of multiple [ion] i (Heiny et al 2019; DiFranco et al 2019; for measurably-large perturbations, an AP train (not a single AP) would be needed).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…By 1200-APs in SM-CD ( Figure 2A ), [Na + ] I rises almost 25 mM above steady-state whereas post-one-AP, [Na + ] I increases <0.05 mM. For contraction-inhibited SMFs (current or voltage-clamped), a new 4-microelectrode technique enables simultaneous monitoring of multiple [ion] i (Heiny et al 2019; DiFranco et al 2019; for measurably-large perturbations, an AP train (not a single AP) would be needed).…”
Section: Resultsmentioning
confidence: 99%
“…Recently-developed cell-physiological techniques (Heiny et al 2019; DiFranco et al 2019) could make it possible to obtain concurrent SMF [ion] i data (plus V m (t)) along the lines of Figure 2A , while for whole tissue in humans, MRI advances are allowing for the non-invasive probing of ion homeostatic parameters in healthy, injured and diseased subjects (e.g., Hammon et al 2015; Dahlmann et al 2016, Gerhalter et al 2017, 2019; Zhang et al 2020). The accessible theoretical framework process presented here for SMF ion homeostasis as a P-L/D process should help guide investigative directions and facilitate interpretation of new data streams.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…DiFranco et al reported on a chloride-selective microelectrode using [9]-mercuracarborand-3 as an ionophore. 191 The fabricated Cl − -selective microelectrode demonstrated a linear response in the concentration range of 10 −3 −10 −1 M with a slope of 54.3 mV/decade. The sensor was characterized with an improved selectivity against bicarbonate ion (log K Cl − ,HCO 3 − Pot = −2.0).…”
Section: Mittal Et Al Synthesized and Tested An Imine-based Ligand (E...mentioning
confidence: 95%
“…DiFranco et al reported on a chloride-selective microelectrode using [9]-mercuracarborand-3 as an ionophore . The fabricated Cl – -selective microelectrode demonstrated a linear response in the concentration range of 10 –3 –10 –1 M with a slope of 54.3 mV/decade.…”
Section: Miniaturized Ion-selective Electrodesmentioning
confidence: 99%