2015
DOI: 10.1039/c5ay01311a
|View full text |Cite
|
Sign up to set email alerts
|

A highly selective and sensitive spectrophotometric method for the determination of selenium using 2-hydroxy-1-napthaldehyde-orthoaminophenol

Abstract: A very simple, ultra-sensitive and highly selective non-extractive spectrophotometric method for the determination of trace amounts of selenium using 2-hydroxy-1-napthaldehyde-orthoaminophenol (HNA-OAP) has been developed. HNA-OAP reacts in slightly acidic (7 Â 10 À6 to 3.5 Â 10 À5 M H 2 SO 4 ) aquatic media with selenium(IV) in 40% N,N-dimethylformamide (DMF) to produce a highly absorbent orange red chelate, which has an absorption maximum at 509 nm. The absorbance intensity of the metal-chelate reaches a con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…The peak at 1658.78 cm -1 con rms the presence of C=N stretching band (Fig. S1) [31]. The total number of carbon was con rmed by 13…”
Section: Resultsmentioning
confidence: 83%
“…The peak at 1658.78 cm -1 con rms the presence of C=N stretching band (Fig. S1) [31]. The total number of carbon was con rmed by 13…”
Section: Resultsmentioning
confidence: 83%
“…The detection limits of calcium, magnesium, silicon, sodium, iron, and selenium were 50 µg Ca/L, 10 µg Mg/L, 2 mg Si/L, 20 µg Na/L, 50 µg Fe/L, and 1 µg Se/L, respectively. In order to cross check the Se(IV) concentrations, the determination was also conducted by following the Ahmed et al (2015) spectrophotometric analytical method (detection limit 1 µg/L) [36], using the spectrometer UV-VIS HITACHI U-5100. Nitrate, chloride, and sulfate were measured with the Alltech 600 ion chromatography system, using an Allsep anion, 150 mm × 4.6 mm, 7 µm, PEEK 51209 column and applying a 1.7 mM NaHCO 3 /1.8 mM Na 2 CO 3 (supplied by Merck, >99.5% purity) solution as eluent.…”
Section: Methodsmentioning
confidence: 99%
“…There are many analytical techniques with their self-advantages and disadvantages, such as capillary electrophoresis online coupled with hydride generation-atomic fluorescence spectrometry (CE/HG AFS) 2 , inductively coupled plasma mass spectrometry (ICP MS) after a separation and preconcentration procedure 4,7 , spectrophotometry with and without preconcentration 8,9 , graphite furnace atomic absorption spectrometric (GF AAS) after preconcentration with coprecipitation 10 , electrothermal atomic absorption spectrometry (ET AAS) 11 , inductively coupled plasma optical emission spectrometry with hydride generation (HG ICP OES) 12 , atomic absorption spectrometry with hydride generation (HG AAS) 13 , and high performance liquid chromatography with UV detection (HPLC) [14][15][16][17] in literature for speciation analysis of inorganic selenium species.…”
Section: Introductionmentioning
confidence: 99%