2012
DOI: 10.1007/s10103-012-1126-z
|View full text |Cite
|
Sign up to set email alerts
|

A high-throughput comparative characterization of laser-induced soft tissue damage using 3D digital microscopy

Abstract: 3D digital microscopy was used to develop a rapid alternative approach to quantify the effects of specific laser parameters on soft tissue ablation and charring in vitro without the use of conventional tissue processing techniques. Two diode lasers operating at 810 and 980 nm wavelengths were used to ablate three tissue types (bovine liver, turkey breast, and bovine muscle) at varying laser power (0.3, 1.0, and 2.0 W) and velocities (1-50 mm/s). Spectrophotometric analyses were performed on each tissue to dete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…Numerous investigations on the interaction between diode lasers and soft biologic tissues are available [12][13][14][15][16][17][18]26,34]. However, these studies focus on the effectiveness of direct laser surgery, which is difficult to compare with hot-tip surgery.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Numerous investigations on the interaction between diode lasers and soft biologic tissues are available [12][13][14][15][16][17][18]26,34]. However, these studies focus on the effectiveness of direct laser surgery, which is difficult to compare with hot-tip surgery.…”
Section: Introductionmentioning
confidence: 99%
“…Diode laser radiation with a wavelength of (980 AE 10) nm is one of the most widely used lasers in dentistry and dermatology [14][15][16][17][18]. The average power of these lasers for medical application does not exceed 10-15 W [12][13][14][15][16][17][18], with rare exceptions [20,21].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…34 Three-dimensional digital microscopy was used to develop a rapid alternative approach for quantifying the effects of specific laser parameters on soft tissue ablation and charring. 35 Furthermore, thermal monitoring has been measured using thermography to analyze temperature development. 36 Robot-assisted laser tissue soldering was evaluated by measuring the tearing forces.…”
Section: Introductionmentioning
confidence: 99%