2016
DOI: 10.1016/j.jpowsour.2016.08.083
|View full text |Cite
|
Sign up to set email alerts
|

A high temperature study on thermodynamic, thermal expansion and electrical properties of BaCe0.4Zr0.4Y0.2O3−δ proton conductor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

6
35
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(42 citation statements)
references
References 37 publications
6
35
0
Order By: Relevance
“…The high-frequency arc corresponds to the total BCZY impedance due to the overlap between bulk and grain boundary conductivity contributions. 13 The conductivity σ was obtained from the real axis interception of the high frequency arc (see σ −1 in Figure 1a), normalized by geometry and then corrected for the sample porosity (∼22%) according to our previous work. 13 So, for instance, at 400°C in wet synthetic air, BCZY displayed a high frequency arc with σ ≈ 0.002 S cm −1 , a relaxation frequency f max = 100 kHz, and capacitance C = 8 nFcm −1 .…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…The high-frequency arc corresponds to the total BCZY impedance due to the overlap between bulk and grain boundary conductivity contributions. 13 The conductivity σ was obtained from the real axis interception of the high frequency arc (see σ −1 in Figure 1a), normalized by geometry and then corrected for the sample porosity (∼22%) according to our previous work. 13 So, for instance, at 400°C in wet synthetic air, BCZY displayed a high frequency arc with σ ≈ 0.002 S cm −1 , a relaxation frequency f max = 100 kHz, and capacitance C = 8 nFcm −1 .…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…The density of fresh dense pellet of BCZP was measured by Archimedes method through hydrostatic weighing using the same electrobalance and diethyl phthalate as the immersion uid [30,31]. CO 2 tolerance must be evaluated through accelerated ageing tests due to Ba basicity and some gas impurities could affect the performance of the material under operating conditions.…”
Section: Methodsmentioning
confidence: 99%
“…Previous results demonstrated that the loss or incorporation of interstitial protons into the crystal structure cause distortions of lattice parameters and ionic conductivity [31]. BCZP was studied by HT-XRD under dry synthetic air to determine if such distortions are present in this compound.…”
Section: Methodsmentioning
confidence: 99%
“…BaZr-or/and BaCe-based oxides. BaCe-and BaZr-based oxides have structures that allow transporting protons through their crystal lattice, which makes them attractive protonic conductor electrolytes [92]. While BaCeO 3 -based compounds present high conductivity and low chemical stability, BaZrO 3based ones exhibit the exact opposite [93,94].…”
Section: Protonic Conductorsmentioning
confidence: 99%
“…Oxides containing both Ce and Zr are also present in literature. Basbus et al [92] reported a study on BaCe 0.4 Zr 0.4 Y 0.2 O 3-d (BCZY) which was synthesized by a solid state reaction with amounts of BaCO 3 , CeO 2 , ZrO 2 and Y 2 O 3 . A crystal structure with cubic symmetry was observed.…”
Section: Protonic Conductorsmentioning
confidence: 99%