2018
DOI: 10.1109/tpel.2017.2702207
|View full text |Cite
|
Sign up to set email alerts
|

A High Step-Up Ratio Soft-Switching DC–DC Converter for Interconnection of MVDC and HVDC Grids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
20
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 94 publications
(20 citation statements)
references
References 38 publications
0
20
0
Order By: Relevance
“…doi.org/10.53272/icrrd.v4i1. 3 Controller provides the logic to the rest of the system for looking at the rectifier and batteries and distribution and giving those operating commands into the status and functionality of the unit. The DC system provides 128.4V to the consumers in the power plant.…”
Section: Controllermentioning
confidence: 99%
See 1 more Smart Citation
“…doi.org/10.53272/icrrd.v4i1. 3 Controller provides the logic to the rest of the system for looking at the rectifier and batteries and distribution and giving those operating commands into the status and functionality of the unit. The DC system provides 128.4V to the consumers in the power plant.…”
Section: Controllermentioning
confidence: 99%
“…Another main objective of this study is mainly to understand the each & every point of the problem solving / continual improvement process in Plant and maintaining this properly and can get the best efficiency. The generated voltage is then stepped up to a higher voltage for transmission, as transmission losses are lower at higher voltages [3]. The transmitted electrical power is then stepped down at grid stations.…”
Section: Introductionmentioning
confidence: 99%
“…Interactions between the boost converter and disturbance rejection have been shown [30]. Bi-directional DC-DC high-efficiency interconnections in MVDC and HVDC converters have been discussed in combination with two-level MMCs [31][32][33]. Modeling of MVDC multidrive systems for power quality analysis and harmonic injection is discussed in [34].…”
Section: Introductionmentioning
confidence: 99%
“…To interconnect DC transmission lines with different voltage levels, DC-DC converters will be used. A number of DC-DC topologies have been proposed in the literature, such as the front-to-front type DC-DC [1,2], the multiple dual active bridge DC-DC [3], the multilevel modular DC-DC [4][5][6][7], the LCL DC-DC [8,9], the DC-DC autotransformer (DC AUTO) [10][11][12][13][14][15], and the hybrid cascaded transformer-less DC-DC [16], the high step-up ratio softswitching DC-DC converter [17], the medium-voltage high-power DC-DC converter for DC distribution systems [18], and the multifunctional full-bridge DC-DC LLC resonant converter building block [19].…”
Section: Introductionmentioning
confidence: 99%