2013
DOI: 10.1002/rcm.6514
|View full text |Cite
|
Sign up to set email alerts
|

A high‐speed liquid chromatography/tandem mass spectrometry platform using multiplexed multiple‐injection chromatography controlled by single software and its application in discovery ADME screening

Abstract: RATIONALE:Multiplexed liquid chromatography (LC) coupled with multiple-injection-chromatogram acquisition has emerged as the method of choice for high-speed discovery bioanalysis, because it significantly reduces injection-to-injection cycle time while maintaining the chromatography quality. Historically, systems utilizing this approach had been custom built, and therefore relied on custom software tools to communicate with multiple vendor software for system control, which lacked transferability, flexibility … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…11 To obtain the optimum selected reaction monitoring (SRM) conditions for sample analysis, MS/MS optimization for each compound was performed using DiscoveryQuant as reported previously. 12 A 5 µL aliquot of sample was injected and the separation was carried out on a Kinetex XB-C18 column (2.6 µm, 2.1 × 30 mm; Phenomenex, Torrance, CA) under a gradient elution using mobile phases A (0.2% formic acid in water) and B (0.2% formic acid in acetonitrile). The percentage of B was first held at 2% for 5 s and then ramped up to 98% in 25 s, where it was held for 20 s before being brought back to the starting composition.…”
Section: Methodsmentioning
confidence: 99%
“…11 To obtain the optimum selected reaction monitoring (SRM) conditions for sample analysis, MS/MS optimization for each compound was performed using DiscoveryQuant as reported previously. 12 A 5 µL aliquot of sample was injected and the separation was carried out on a Kinetex XB-C18 column (2.6 µm, 2.1 × 30 mm; Phenomenex, Torrance, CA) under a gradient elution using mobile phases A (0.2% formic acid in water) and B (0.2% formic acid in acetonitrile). The percentage of B was first held at 2% for 5 s and then ramped up to 98% in 25 s, where it was held for 20 s before being brought back to the starting composition.…”
Section: Methodsmentioning
confidence: 99%
“…The multiplexed LC-MS approach involves coupling two or four independent LCs into the same mass spectrometer with a switching valve, making staggered injections onto the different LCs, and collecting MS data from the retention window of each LC channel. A speed of 15-30 s can be achieved with a 2Â or 4Â multiplexed LC-MS system (Kapinos et al, 2017;Zhang et al, 2010;Zhang et al, 2013). Direct online solid-phase extraction (SPE) is another LC-based approach.…”
Section: Development Of Acoustic Ejection Mass Spectrometrymentioning
confidence: 99%
“…8 In an effort to minimize MS idle time, the multiplexed LC approach combined with multiple injection chromatography for data acquisition yields a typical analysis speed of 0.5 min per sample. 9,10 An even faster injection-to-injection cycle time of 5–10 s has been achieved on the RapidFire system (Agilent Technologies, Santa Clara, CA), where the chromatographic separation is simply reduced to a minimum of online solid-phase extraction. 11,12 Sample pooling for cassette LC-MS analysis has also been seen for high-throughput nanoscale synthesis 3 and various in vitro profiling assays 13,14 to alleviate the analytical workload.…”
Section: Introductionmentioning
confidence: 99%