Abstract: A prototype multidetector shadow-shield whole-body counter is presented to be used as a monitor of internal contamination and as a tool in clinical research. The counter is equipped with 16 NaI(Tl) detectors located in the central region of a shielded tunnel surrounding the subject to be measured. The accuracy of the counting efficacy predictions was tested in a group of adults with various body shapes and sizes using X-ray absorptiometry. The precision of the total body potassium measurements allows the use o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 13 publications
0
9
0
Order By: Relevance
“…In March, six workers received a high internal exposure of over 200 mSv as measured by a whole-body counter. 7 The maximum estimated exposure per worker was 670.4 mSv. 5 The workers subjected to such exposure may inhale radiation particles due to respirator leakage, or may not have worn respirators because of inaccurate exposure assessments or inadequate emergency operations.…”
Section: Radiationmentioning
confidence: 97%
See 1 more Smart Citation
“…In March, six workers received a high internal exposure of over 200 mSv as measured by a whole-body counter. 7 The maximum estimated exposure per worker was 670.4 mSv. 5 The workers subjected to such exposure may inhale radiation particles due to respirator leakage, or may not have worn respirators because of inaccurate exposure assessments or inadequate emergency operations.…”
Section: Radiationmentioning
confidence: 97%
“…Table 1 shows the external, internal and total exposure of the workers to radiation from March to May 2011. In March, six workers received a high internal exposure of over 200 mSv as measured by a whole-body counter 7. The maximum estimated exposure per worker was 670.4 mSv 5.…”
Section: Hazards Of the Job And The Workplacementioning
confidence: 99%
“…The upgraded UIMPL WBC is a shadow-shield counter with a moving bed in a 201-cm-long tunnel made of low activity 10-cm-thick lead bricks (Kalef-Ezra et al 2011). A 60.0-cm-wide and 48.4-cm-high opening through the lead bricks allows for the patient positioned supine on a metallic couch to pass with constant velocity through it (Fig.…”
Section: Whole Body Counter Descriptionmentioning
confidence: 99%
“…The counter was upgraded in an attempt to improve its performance characteristics and facilitate its clinical use (Kalef-Ezra et al 2011). In particular, basic goals of the upgrading process were the improvement of measurement precision and the reduction of the minimum detectable activity coupled with high counting efficiency and minimal dependence of the efficiency on the activity distribution in the human body.…”
Section: Introductionmentioning
confidence: 99%
“…A prototype shadow-shield whole body counter was designed, constructed and tested at the University of Ioannina Medical Physics Laboratory (UIMPL) as a direct monitor of internal contamination and as a tool in clinical research [1]. The counter is ___________________________________________ *correspondence to: jkalef@cc.uoi.gr 21st Hellenic Symposium on Nuclear Physics an upgraded version of a counter in use since 1986, that was equipped with two NaI(Tl) detectors [2].…”
Section: Introductionmentioning
confidence: 99%