2014
DOI: 10.1016/j.nimb.2014.05.016
|View full text |Cite
|
Sign up to set email alerts
|

A high-resolution multi-reflection time-of-flight mass spectrograph for precision mass measurements at RIKEN/SLOWRI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
42
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 73 publications
(52 citation statements)
references
References 53 publications
2
42
0
Order By: Relevance
“…This capability has until now been limited to storage rings. As we have demonstrated [13,16], and herein further demonstrate, the MRTOF-MS allows for a considerably less complex data analysis than that used for storage rings. As the first step toward mass spectrographic identification of superheavy elements (SHEs), a gas cell connected to an MRTOF-MS was installed in front of the gas-filled recoil ion separator GARIS-II [6].…”
mentioning
confidence: 54%
See 2 more Smart Citations
“…This capability has until now been limited to storage rings. As we have demonstrated [13,16], and herein further demonstrate, the MRTOF-MS allows for a considerably less complex data analysis than that used for storage rings. As the first step toward mass spectrographic identification of superheavy elements (SHEs), a gas cell connected to an MRTOF-MS was installed in front of the gas-filled recoil ion separator GARIS-II [6].…”
mentioning
confidence: 54%
“…By momentarily lowering the outermost potential on either mirror, ions can be allowed to enter or exit the MRTOF-MS. A detailed description can be found in Ref. [16].…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, a compact setup can be maintained while providing high mass resolving powers up to about 200 000 for millisecond flight times [36][37][38]. In contrast to conventional ToF-MS where the flight path limits the achievable precision to typically a level of 10 −6 these devices can reach relative mass uncertainties of about 10 −7 or even below [39]. MR-ToF-MS devices are thus suitable for mass measurements with a precision usually required to study global nuclear structure trends.…”
Section: Nobel Symposium Ns160 -Chemistry and Physics Of Heavy And Sumentioning
confidence: 99%
“…In the last few years, these compact devices have been commissioned at GSI [95,96], RIKEN [97], and ISOLDE/CERN [98]. One of the first online mass measurements was performed at RIKEN using 8 Li + (T 1/2 = 838 ms).…”
Section: The Achievable Relative Precision Of Pmts With the Tof-icr Tmentioning
confidence: 99%