2004
DOI: 10.1016/j.jasms.2003.10.005
|View full text |Cite
|
Sign up to set email alerts
|

A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces

Abstract: A new design for a high pressure MALDI-FTMS instrument is described and initial data are shown. The instrument incorporates a large, 10 cm x 10 cm, sample translation stage to accommodate and position the MALDI target. The new instrument allows coupling to a wide variety of surface techniques such as gel electrophoresis or surface plasmon resonance. Coupling to thin layer chromatography is shown. Furthermore, a new nozzle design allows high pressure collisional cooling sufficient to stabilize gangliosides whil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
53
0
2

Year Published

2004
2004
2015
2015

Publication Types

Select...
5
5

Relationship

4
6

Authors

Journals

citations
Cited by 59 publications
(55 citation statements)
references
References 33 publications
(46 reference statements)
0
53
0
2
Order By: Relevance
“…For this reason, considerable attention needs to be given to the search for the proper matrixto-analyte ratio, to obtain clean spectra with minimum matrix adduction. On the other hand, the prOTOF design supplies a constant cooling rate in the ionization source, whereas the FTMS instrument with the VC source [37] allows variation of the timing of the cooling gas pulse, with respect to the ionization/desorption event. Coordination of these two events may help reduce the amount of matrix adducts, if declustering voltage is applied immediately after the ionization, rather than simultaneously with it.…”
Section: Discussionmentioning
confidence: 99%
“…For this reason, considerable attention needs to be given to the search for the proper matrixto-analyte ratio, to obtain clean spectra with minimum matrix adduction. On the other hand, the prOTOF design supplies a constant cooling rate in the ionization source, whereas the FTMS instrument with the VC source [37] allows variation of the timing of the cooling gas pulse, with respect to the ionization/desorption event. Coordination of these two events may help reduce the amount of matrix adducts, if declustering voltage is applied immediately after the ionization, rather than simultaneously with it.…”
Section: Discussionmentioning
confidence: 99%
“…Due to the high mass accuracy and resolving power of an FTMS, MALDI-FTMS [5][6][7] and ESI-FTMS [8,9] are becoming the instruments of choice for proteomics [10], and experiments on proteins and large fragments of proteins, so called "top-down" [11][12][13][14] mass spectrometry. These experiments tend to slow down due to the lack of sophisticated methods for automatic spectrum analysis.…”
Section: T He Wide Employment Of Fourier Transform Massmentioning
confidence: 99%
“…We recently reported an optimized procedure for (Ϫ)nanoESI-QTOF MS and tandem MS for the characterization of a native ganglioside mixture from brain tissue [27][28][29][30]. This procedure requires elevated parameter values for ionization, and an extended time for MS/MS signal acquisition, which suggests that relatively high sample consumption is needed for identification and structural elucidation.…”
mentioning
confidence: 99%