Abstract: a b s t r a c tMolecular imprinting technology is becoming a versatile tool for the preparation of tailor-made molecular recognition elements. This work investigates the performance of a hemin-modified molecularly imprinted polymer (MIP) used as an amperometric sensor for the detection of 4-aminophenol (4-APh). MIP particles were prepared by the precipitation polymerization method with hemin introduced as the catalytic center to mimic the active site of peroxidase. 4-APh was used as the template molecule, meth… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
14
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 67 publications
(16 citation statements)
references
References 30 publications
2
14
0
Order By: Relevance
“…Electrochemical biosensors are widely synthesized by electropolymerization of such monomers as pyrrole [101], aniline [104], o -phenylenediamine (o-PD) [125,126], phenol [32], aminophenol [110,111,127] and EDOT [128,129], self-assembled monolayers (SAMs) [2,130,131] and sol-gel [93] materials.…”
Section: Electrochemical Transductionmentioning
confidence: 99%
“…Electrochemical biosensors are widely synthesized by electropolymerization of such monomers as pyrrole [101], aniline [104], o -phenylenediamine (o-PD) [125,126], phenol [32], aminophenol [110,111,127] and EDOT [128,129], self-assembled monolayers (SAMs) [2,130,131] and sol-gel [93] materials.…”
Section: Electrochemical Transductionmentioning
confidence: 99%
“…19 Neto et al demonstrated the performance of a heminmodified molecularly imprinted polymer (MIP) used as an amperometric sensor for the detection of 4-AP. 20 Shiroma et al developed a sensitive microfluidic paper-based device for electrochemical detection of paracetamol and 4-AP. 21 De Bleye employed a quantified 4-AP in a pharmaceutical formulation containing acetaminophen using surface-enhanced Raman scattering.…”
Section: Introductionmentioning
confidence: 99%
“…The MIP column has a large number of "separation plates" which results in a remarka- bly low cross-reactivity towards structurally similar substances. Later a glassy carbon electrode was covered with a suspension of a heme-based bulk MIP and it responded linearly to p-aminophenol with a LOD of 3 mM and no interfering signals for o-aminophenol, catechol and guaiacol [14].…”
Section: Catalytically Active Mip Architecturesmentioning
confidence: 99%