2007
DOI: 10.1016/j.foodchem.2006.03.007
|View full text |Cite
|
Sign up to set email alerts
|

A headspace solid-phase microextraction method of use in monitoring hexanal and pentane during storage: Application to liquid infant foods and powdered infant formulas

Abstract: The determination of two secondary lipid oxidation compounds (hexanal and pentane) in liquid infant foods using a headspace solidphase microextraction gas chromatographic (HS-SPME-GC) method has been developed and validated.The HS-SPME analytical conditions (fibre position, equilibration and sampling times) were selected. The analytical parameters of the method (linearity: hexanal from 2.48 to 84.78 ng/g, pentane from 6.21 to 79.55 ng/g; precision: hexanal -2.87%, pentane -2.34-3.46%; recovery: hexanal -106.60… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
33
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 57 publications
(33 citation statements)
references
References 34 publications
0
33
0
Order By: Relevance
“…One of the most studied volatile biomarker for dairy oxidative stress is hexanal since it is one of the major products of fat oxidation, which increases during storage. Hexanal is produced from the oxidation of n‐6 polyunsaturated fatty acids, like linoleic acid, and is usually associated with grassy or metallic‐like off‐flavor in milk and butter . Recently, Asaduzzaman et al monitored milk oxidative stress by following hexanal evolution at 4°C by PTR‐MS.…”
Section: Resultsmentioning
confidence: 99%
“…One of the most studied volatile biomarker for dairy oxidative stress is hexanal since it is one of the major products of fat oxidation, which increases during storage. Hexanal is produced from the oxidation of n‐6 polyunsaturated fatty acids, like linoleic acid, and is usually associated with grassy or metallic‐like off‐flavor in milk and butter . Recently, Asaduzzaman et al monitored milk oxidative stress by following hexanal evolution at 4°C by PTR‐MS.…”
Section: Resultsmentioning
confidence: 99%
“…On the other hand, using SPME resulted in a richer chromatogram (Figure 1-B), while being cleaner and faster way of sample preparation and injection. Furthermore, the reproducibility and robustness of the method is well described and it is a widely adopted methodology in quality control in food science (Bianchi et al, 2007;García-Llatas et al, 2007;Plutowska and Wardencki, 2007;Romeo et al, 2007), pesticides, environmental science and in volatiles substances in general (Pacolay et al, 2006;Balakrishnan et al, 2006;Kayali et al, 2006;Luan et al 2006;Rodríguez et al, 2006;Kolb and Püttmann, 2006).…”
Section: Resultsmentioning
confidence: 99%
“…As previously mentioned, hydroperoxides are highly reactive compounds that decompose rapidly, yielding a complex mixture of volatile and non-volatile compounds such as aldehydes, ketones, hydrocarbons etc. which may affect the overall quality of product (García-Llatas, Legarda, Romero, Abellá n, & Farré , 2006). Prior to irradiation, nine compounds were identified belonging to six chemical classes of aldehydes, ketones, alkanes, alcohols and aromatic hydrocarbons.…”
Section: Volatile Compoundsmentioning