2022
DOI: 10.1155/2022/9374638
|View full text |Cite
|
Sign up to set email alerts
|

A Grid-Connected Solar PV/Wind Turbine Based Hybrid Energy System Using ANFIS Controller for Hybrid Series Active Power Filter to Improve the Power Quality

Abstract: The current needs of more nonlinear loads and the frequent usage of single-phase loads in three-phase system drastically create power quality issues in the grid-connected system. As a consequence, it creates an undesirable power quality issue (PQI) in the form of a change in the nature of voltage and current magnitude and waveforms in the power system. The voltage-related PQI leads to a huge disturbance in the system when compared with the current-related PQI. The hybrid series active power filter provides gri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 37 publications
0
4
0
1
Order By: Relevance
“…Berbagai upaya untuk mereduksi harmonisa dan peningkatan kualitas daya pada sistem PLTS on grid, antara lain dengan memanfaatkan kompensator distribusi statis, yang dilengkapi dengan sistem penyimpanan energi baterai [12] dapat menentukan kesesuaian metode untuk mitigasi harmonisa dan peningkatan kualitas daya. Reduksi total distorsi harmonisasi pada luaran inverter satu-fasa dengan desain filter pasif menggunakan model simulasi SPICE [13], P. Cholamuthu et al, mengusulkan desain Filter daya aktif seri hybrid untuk mereduksi harmonik berbasis-ANFIS, sesuai dengan standar IEEE 519-1992, model prototipe yang diusulkan terbukti menunjukkan bahwa sistem pengiriman daya bekerja secara efektif mengurangi distorsi harmonik total sekitar 30% [14].…”
Section: Pendahuluanunclassified
“…Berbagai upaya untuk mereduksi harmonisa dan peningkatan kualitas daya pada sistem PLTS on grid, antara lain dengan memanfaatkan kompensator distribusi statis, yang dilengkapi dengan sistem penyimpanan energi baterai [12] dapat menentukan kesesuaian metode untuk mitigasi harmonisa dan peningkatan kualitas daya. Reduksi total distorsi harmonisasi pada luaran inverter satu-fasa dengan desain filter pasif menggunakan model simulasi SPICE [13], P. Cholamuthu et al, mengusulkan desain Filter daya aktif seri hybrid untuk mereduksi harmonik berbasis-ANFIS, sesuai dengan standar IEEE 519-1992, model prototipe yang diusulkan terbukti menunjukkan bahwa sistem pengiriman daya bekerja secara efektif mengurangi distorsi harmonik total sekitar 30% [14].…”
Section: Pendahuluanunclassified
“…The applications that are related to Grid-connected are used to exchange energy with the utility grid and supply energy for local loads, as opposed to standalone PV systems, which can only offer electricity for distant loads that lack a source of power. The DC current from the PV module is transformed into alternating current in a solar PV system by an inverter that is connected to the grid [17]. After meeting the current demand, the PV system can transmit the excess energy to the grid when it is connected to it.…”
Section: Introductionmentioning
confidence: 99%
“…Te several algorithms that are now in use to regulate DLCV regulation, current control methods, harmonic separation approaches, and SHAPF functioning are described [6]. In the meantime, ANFIS was used to manage the series flter in order to handle voltage-related troubles [7]. Te distributed energy system, which mixes PV and wind, was constructed to minimize load fuctuations and enable a smooth transition between the grid and the island [8].…”
Section: Introductionmentioning
confidence: 99%