2023
DOI: 10.3390/su151713275
|View full text |Cite
|
Sign up to set email alerts
|

A Green Approach to Preparing Vaterite CaCO3 for Clean Utilization of Steamed Ammonia Liquid Waste and CO2 Mineralization

Xuewen Song,
Yuxin Tuo,
Dan Li
et al.

Abstract: In the salt lake industry, large amounts of steamed ammonia liquid waste are discharged as byproducts. The conversion of the residues into high value-added vaterite-phase calcium carbonate products for industrial applications is highly desirable. In this research, the feasibility of preparing vaterite-phase CaCO3 in different CaCl2-CO2-MOH-H2O systems using steamed ammonia liquid waste was studied in the absence of additives. The effects of initial CaCl2 concentration, stirring speed and CO2 flow rate on the c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
0
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 49 publications
0
0
1
Order By: Relevance
“…L. Freddy's 46 research indicated that the pH increased when the concentrations of CaCl 2 and NaCO 3 increased, and the pH of the CaCl 2 and NaCO 3 reaction system is higher than that of the CaCl 2 and (NH 4 ) 2 CO 3 reaction system. However, our study is contrary to this result, as our previous research showed 47 that the pH of the steamed ammonia liquid waste is much higher than that of the same CaCl 2 concentration; the pH reached above 11. However, NaCl solution is a kind of salt and the pH is close to neutral, so the pH of the reaction system continues to decrease the higher the concentration of NaCl in the reaction system.…”
Section: Effect Of Na + Concentration On Reaction Ph and Conductivitycontrasting
confidence: 99%
“…L. Freddy's 46 research indicated that the pH increased when the concentrations of CaCl 2 and NaCO 3 increased, and the pH of the CaCl 2 and NaCO 3 reaction system is higher than that of the CaCl 2 and (NH 4 ) 2 CO 3 reaction system. However, our study is contrary to this result, as our previous research showed 47 that the pH of the steamed ammonia liquid waste is much higher than that of the same CaCl 2 concentration; the pH reached above 11. However, NaCl solution is a kind of salt and the pH is close to neutral, so the pH of the reaction system continues to decrease the higher the concentration of NaCl in the reaction system.…”
Section: Effect Of Na + Concentration On Reaction Ph and Conductivitycontrasting
confidence: 99%