2000
DOI: 10.1109/77.828494
|View full text |Cite
|
Sign up to set email alerts
|

A genetic algorithm approach to the design of split coil magnets for MRI

Abstract: Absrrmf -Innovntive,open magnet designs for Magnetic Resonance Imaging (MRI) of p r t s of hiimmn body hnve been recently proposed. 'I'lisse open configuritlons require notrl)le skill in the design phase to obtain sntisfnctory perfnrninnre i n terms of compnctness niid field homogenelty: optimization techniques thus seems adequate to m i s t the designer of such devices. A novel o~itinilxation sclicmc, based on n gciietlc nlgorithm (CA) hms been Implcmctited fnr the resolution nf this problem, Tlic G h seems w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2002
2002
2018
2018

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 5 publications
0
9
0
Order By: Relevance
“…A number of advancements in design have seen the development of improved and cheaper technologies in magnet construction and performance [2][3][4][5][6][7][8][9], which provide clear benefits to the community in the form of more accurate and insightful diagnostic and preventative healthcare. Recent emerging technologies have provided practitioners with the ability to obtain higher resolution images, and perform faster scans, resulting in greater patient throughput and improved patient comfort.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A number of advancements in design have seen the development of improved and cheaper technologies in magnet construction and performance [2][3][4][5][6][7][8][9], which provide clear benefits to the community in the form of more accurate and insightful diagnostic and preventative healthcare. Recent emerging technologies have provided practitioners with the ability to obtain higher resolution images, and perform faster scans, resulting in greater patient throughput and improved patient comfort.…”
Section: Introductionmentioning
confidence: 99%
“…Attempts have been made to address the concerns of weight, size and magnetic field nonlinearity [2][3][4] in these magnet systems, with the hope of manufacturing less costly systems.…”
Section: Introductionmentioning
confidence: 99%
“…In the analysis of MRI magnets a spherical harmonics expansion of the field can be used: (1) where are the coordinate of the field point and are the Legendre functions of the first kind.…”
Section: Sensitivity Analysis In Mri Magnet Designmentioning
confidence: 99%
“…This design has been obtained by means of an optimized design method [1]. In the nominal configuration the device produces a central field of 3 T with a field homogeneity of 5 ppm over a 10 cm Diameter Spherical Volume (DSV).…”
Section: Assessment Of Performance For the Proposed Algorithmmentioning
confidence: 99%
See 1 more Smart Citation