Medical Imaging 2018: Physics of Medical Imaging 2018
DOI: 10.1117/12.2293776
|View full text |Cite
|
Sign up to set email alerts
|

A general CT reconstruction algorithm for model-based material decomposition

Abstract: Material decomposition in CT has the potential to reduce artifacts and improve quantitative accuracy by utilizing spectral models and multi-energy scans. In this work we present a novel Model-Based Material Decomposition (MBMD) method based on an existing iterative reconstruction algorithm derived from a general non-linear forward model. A digital water phantom with inserts containing different concentrations of calcium was scanned on a kV switching system. We used the presented method to simultaneously recons… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 20 publications
0
12
0
Order By: Relevance
“…This suggests that MBMD may be used with other non-traditional acquisition protocols such as unconventional filtration (Yu et al 2016, Xi et al 2017, Stayman and Tilley 2018, multiple limited angle scans (Chen et al 2017) and systems with multiple axially oriented x-ray sources (Gang et al 2018). Related work has applied the MBMD approach to kV-switching (Tilley et al 2018b) and x-ray beam spectral filtering (Stayman and Tilley 2018) scenarios. These studies further support the robustness of this approach, demonstrating its application in additional acquisition strategies.…”
Section: Discussionmentioning
confidence: 99%
“…This suggests that MBMD may be used with other non-traditional acquisition protocols such as unconventional filtration (Yu et al 2016, Xi et al 2017, Stayman and Tilley 2018, multiple limited angle scans (Chen et al 2017) and systems with multiple axially oriented x-ray sources (Gang et al 2018). Related work has applied the MBMD approach to kV-switching (Tilley et al 2018b) and x-ray beam spectral filtering (Stayman and Tilley 2018) scenarios. These studies further support the robustness of this approach, demonstrating its application in additional acquisition strategies.…”
Section: Discussionmentioning
confidence: 99%
“…50 mg/mL) and the maximum water concentration (i.e. 1,000 mg/mL) in the phantom 5 . Detector pixels were binned by 6 × 6 during projection postprocessing before reconstructions.…”
Section: Simulation Studymentioning
confidence: 98%
“…m {k} (ε) is the energy-dependent mass-attenuation coefficient of the base material k, and ρ {k} is the unknown local density (concentration). We have shown that this forward model can be written in a general matrix form 5 :…”
Section: Known-component Model-based Materials Decomposition (Kc-mbmd)mentioning
confidence: 99%
See 2 more Smart Citations