2014
DOI: 10.5194/amt-7-3263-2014
|View full text |Cite
|
Sign up to set email alerts
|

A gas chromatograph for quantification of peroxycarboxylic nitric anhydrides calibrated by thermal dissociation cavity ring-down spectroscopy

Abstract: Abstract. The peroxycarboxylic nitric anhydrides (PANs, molecular formula: RC(O)O 2 NO 2 ) can readily be observed by gas chromatography (PAN-GC) coupled to electron capture detection. Calibration of a PAN-GC remains a challenge, because the response factors differ for each of the PANs, and because their synthesis in sufficiently high purity is non-trivial, in particular for PANs containing unsaturated side chains. In this manuscript, a PAN-GC and its calibration using diffusion standards, whose output was qua… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
24
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(26 citation statements)
references
References 67 publications
(112 reference statements)
2
24
0
Order By: Relevance
“…inner diameter (ID) Teflon ™ inlet at a height of 4 m above ground; the setup is depicted in Fig. 3 of Tokarek et al (2014). A scroll pump whose flow rate was throttled using a 50 standard litres per minute (slpm) capacity mass flow controller was connected to the end of the common inlet to minimize the residence time of the sampled air and to reduce inlet "aging", i.e., accumulation of aerosol on filters of individual instruments, whose inlets tapped into the main inlet line at 90 • .…”
Section: Measurement Techniquesmentioning
confidence: 99%
See 3 more Smart Citations
“…inner diameter (ID) Teflon ™ inlet at a height of 4 m above ground; the setup is depicted in Fig. 3 of Tokarek et al (2014). A scroll pump whose flow rate was throttled using a 50 standard litres per minute (slpm) capacity mass flow controller was connected to the end of the common inlet to minimize the residence time of the sampled air and to reduce inlet "aging", i.e., accumulation of aerosol on filters of individual instruments, whose inlets tapped into the main inlet line at 90 • .…”
Section: Measurement Techniquesmentioning
confidence: 99%
“…Further, the collisional dissociation chamber (CDC) was operated in declustering mode (−22.7 V) to break up ion clusters. Calibrations and matrix effect correction procedures and a time series of the PAN and PPN data were presented by Tokarek et al (2014 The CRDS used in this work was an amalgamated version of two instruments described earlier (Paul and Osthoff, 2010;Odame-Ankrah and Osthoff, 2011), called Improved Detection Instrument for Nitrogen Oxide Species (iDinos) (Odame-Ankrah, 2015). A schematic of the optical layout is shown in Fig.…”
Section: Quantification Of Clno 2 By Iodide Chemical Ionization Mass mentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore, recent work suggests that synthesis of APN standards using acyl chloride compounds should be avoided for reasons of impurities (Tokarek et al, 2014); however, the use of a GC pre-separation step eliminates any possibility of unwanted measurement interferences.…”
Section: Acyl Peroxynitrate (Apns) Synthesis and Calibrationmentioning
confidence: 99%