2017
DOI: 10.1002/etep.2389
|View full text |Cite
|
Sign up to set email alerts
|

A fuzzy-logic-based control methodology for secure operation of a microgrid in interconnected and isolated modes

Abstract: Summary Due to the global concerns regarding the climate change, integration of renewable energy sources is considered as a mitigation approach in electric power generation. This requires advanced frequency and voltage control methodologies to overcome the challenges especially in microgrids. This paper presents a 2‐step frequency and voltage control methodology for microgrids with high penetration of variable renewable energy sources. An optimized Proportional‐Integral controller is designed for a Superconduc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 40 publications
0
7
0
Order By: Relevance
“…To simplify the complexity of solving the MINLP problem, several algorithms such as generalised benders decomposition (GBD), outer approximation (OA), feasibility approach, OA with equality relaxation (OA/ER), generalised OA, and generalised cross decomposition are developed [14]. A number of previous works have applied deterministic and meta-heuristic solution techniques to solve MINLP problems [15][16][17][18][19][20][21][22][23][24][25]. Deterministic methods such as priority list [16], branch and bound (BB) [17], Lagrangian relaxation (LR) [18], and benders decomposition (BD) [22] have been applied to solve MINLP problems.…”
Section: Solution Algorithms For the Coupled Operation Of Natural Gasmentioning
confidence: 99%
See 1 more Smart Citation
“…To simplify the complexity of solving the MINLP problem, several algorithms such as generalised benders decomposition (GBD), outer approximation (OA), feasibility approach, OA with equality relaxation (OA/ER), generalised OA, and generalised cross decomposition are developed [14]. A number of previous works have applied deterministic and meta-heuristic solution techniques to solve MINLP problems [15][16][17][18][19][20][21][22][23][24][25]. Deterministic methods such as priority list [16], branch and bound (BB) [17], Lagrangian relaxation (LR) [18], and benders decomposition (BD) [22] have been applied to solve MINLP problems.…”
Section: Solution Algorithms For the Coupled Operation Of Natural Gasmentioning
confidence: 99%
“…2.1.3 Linepack: Due to the fact that supplying gas from sources take time to reach demand centres (typically hours), linepack [34] is used to meet the rapid changes in the network. The linepack L within a pipe, calculated through combining (8), (23), (24), and considering parameter K as in (25), is shown in (26)…”
Section: Gas Compressorsmentioning
confidence: 99%
“…Therefore, the effectiveness of the proposed controller alongside the system parameter variations and random load fluctuations is also taken into account for further consideration. Ameli et al 20 have proposed a fuzzy based‐PID controller for voltage and frequency regulation of microgrids in interconnected and isolated modes. Patel et al 21 have suggested a fuzzy tilt‐integral‐derivative controller with filter for frequency stabilization in a hybrid microgrid system while Kumar et al 22 have addressed frequency control of isolated microgrid for stochastic wind and PV variation using autoregressive integrated moving average method.…”
Section: Introductionmentioning
confidence: 99%
“…In [15][16][17][18], a unified scheme based on droop control is designed to only change the voltage reference rather than control structure so that inrush currents and voltage distortions of mode transfer can be eliminated. In [19][20][21][22], fuzzy-based parameter regulation is implemented to improve the performance of dynamic response and stability when transferring. However, before getting power supply from the MG system, loads should disconnect from the utility completely [23,24].…”
Section: Introductionmentioning
confidence: 99%