2008
DOI: 10.1109/tim.2007.911703
|View full text |Cite
|
Sign up to set email alerts
|

A Four-Terminal Water-Quality-Monitoring Conductivity Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
0
3

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
3
2

Relationship

0
10

Authors

Journals

citations
Cited by 78 publications
(35 citation statements)
references
References 12 publications
0
32
0
3
Order By: Relevance
“…The conductivity MEA has a better response time (less to 0.1 s) over the commercial conductivity sensors (about 10-30 s), with the similar R square value (>0.95) [30,31], since the four-electrode structure efficiently reduced the effects of polarization and increased the accuracy compared with the two-electrode conductivity structure. Furthermore, the miniature size (<1 mm) of the MEA sensors minimized the impact of the sensor to the solution compared with traditional conductivity sensors (>100 mm) [41]. Due to the close association between conductivity and temperature (Eq.…”
Section: Calibration Of Physical Mea Sensors (Temperature and Conductmentioning
confidence: 99%
“…The conductivity MEA has a better response time (less to 0.1 s) over the commercial conductivity sensors (about 10-30 s), with the similar R square value (>0.95) [30,31], since the four-electrode structure efficiently reduced the effects of polarization and increased the accuracy compared with the two-electrode conductivity structure. Furthermore, the miniature size (<1 mm) of the MEA sensors minimized the impact of the sensor to the solution compared with traditional conductivity sensors (>100 mm) [41]. Due to the close association between conductivity and temperature (Eq.…”
Section: Calibration Of Physical Mea Sensors (Temperature and Conductmentioning
confidence: 99%
“…The molar conductivities of all the electrolyte solutions and of human nail plate immersed therein were determined by a four terminal resistance method 25,30,31 in side-by-side diffusion cells (PermeGear Inc., Bethlehem, PA). The method was that used in Franz diffusion cells by LaCount and Kasting 25 except for variations as described below.…”
Section: Methodsmentioning
confidence: 99%
“…Nevertheless, the contact measurement principle will accelerate the metal corrosion, which will influence the experiment results. For salinity measurement, the conductivity meters [9,10] are the most widely used and two electrodes are exploited to detect the water conductivity, related to the concentrations of the dissolved salt. However, this method can easily cause water polarization [11].…”
Section: Introductionmentioning
confidence: 99%