1982
DOI: 10.1109/tns.1982.4335903
|View full text |Cite
|
Sign up to set email alerts
|

A Four Ring Positron Camera System for Emission Tomography of the Brain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

1985
1985
2008
2008

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(11 citation statements)
references
References 2 publications
0
11
0
Order By: Relevance
“…Early PET images suffered from limited spatial resolution (approximately 15 mm), low sensitivity and insufficient attenuation and scatter correction [3,4]. PET image quality improved with the four-ring PC-384 (Scanditronix) [5], which yielded seven simultaneous, partly overlapping transaxial images and that provided a spatial resolution of 8.4 mm FWHM across 12-mm slices (Fig. 1b) [6] and limited axial reconstruction (Fig.…”
Section: Development Of Pet For Brain Imagingmentioning
confidence: 99%
“…Early PET images suffered from limited spatial resolution (approximately 15 mm), low sensitivity and insufficient attenuation and scatter correction [3,4]. PET image quality improved with the four-ring PC-384 (Scanditronix) [5], which yielded seven simultaneous, partly overlapping transaxial images and that provided a spatial resolution of 8.4 mm FWHM across 12-mm slices (Fig. 1b) [6] and limited axial reconstruction (Fig.…”
Section: Development Of Pet For Brain Imagingmentioning
confidence: 99%
“…("C)-methyl iodide was prepared and used to alkylate the N-dcmcthylated analogues of morphine and prthidine. The products wcrc purified and analysed for identity and radiochemical purity by reversed phase high-pressure liquid chromatography (12). The radio-active samples were filtered through a 0.22 pm membrane filter just hrlbrr administration.…”
Section: Methodsmentioning
confidence: 99%
“…Using positron emission tomography (PET), threedimensional quantitative estimates of drug uptake and elimination at different levels of the spinal column can be obtained in vivo after spinal administration of "C-labelled morphine and pethidine (12,13). The objectives of the present study were: -To characterize the regional distribution of morphine and pethidine after extradural and intrathecal administration.…”
mentioning
confidence: 99%
“…Images were recorded for 12, 40, 600 s at determined periods for 60-90 min and reconstructed according to Eriksson et al (1982). The resolution of the camera was 0.8 cm.…”
Section: Analysis With Positron Emission Tomographymentioning
confidence: 99%